5.0 SAFETY
IRN37–160K–OF & IRN50–200H–OF
http://air.irco.com
7
All pressure containing parts, especially flexible hoses
and their couplings, must be regularly inspected, be
free from defects and be replaced according to the
Manual instructions.
Compressed air can be dangerous if incorrectly
handled. Before doing any work on the unit, ensure that
all pressure is vented from the system and that the
machine cannot be started accidentally.
Avoid bodily contact with compressed air.
The safety valve located in the interstage and
aftercooler must be checked periodically for correct
operation.
Whenever pressure is released through the pressure
relief valve, it is due to excessive pressure in the
system. The cause for the excessive pressure should
be investigated immediately.
Materials
The following substances are used in the
manufacture of this machine and
may
be hazardous
to health if used incorrectly:
. preservative grease
. rust preventative
. compressor oil
WARNING
AVOID INGESTION, SKIN CONTACT AND
INHALATION OF FUMES
For further information, request and consult the coolant
Material Data Sheet (UK ACGP 011/96 –ULTRA
COOLANT ACGP 029/90–food grade coolant. For
USA served areas, use MSDS sheet APDD 236) from
your local IR office, Distributor or Air Center.
Should compressor oil come into contact with the
eyes, then irrigate with water for at least 5 minutes.
Should compressor oil come into contact with the
skin, then wash off immediately.
Consult a physician if large amounts of compressor
oil are ingested.
Consult a physician if compressor oil is inhaled.
Never give fluids or induce vomiting if the patient is
unconscious or having convulsions.
The above information contains data supplied in
support of United Kingdom
Control of Substances
Hazardous to Health
(C.O.S.H.H.) regulations
Transport
When loading or transporting machines ensure that the
specified lifting and tie down points are used.
It is recommended that the machine be moved using
the fork lift slots in the machine base.
Refer to section 8 for reference information.
Electrical
The compressor has high and dangerous voltage in the
motor starter and control box. All installations must be
in accordance with recognized electrical codes. Before
working on the electrical system, be sure to remove
voltage from the system by using a manual disconnect
switch. A circuit breaker or fuse safety switch must be
provided in the electrical supply line leading to the
compressor.
Those responsible for installation of this equipment
must provide suitable grounds, maintenance clearance
and lightning arrestors for all electrical components in
accordance with National and Local code
requirements.
Keep all parts of the body and any hand–held tools or
other conductive objects, away from exposed live parts
of the compressor electrical system. Maintain dry
footing, stand on insulating surfaces and do not contact
any other portion of the compressor when making
adjustments or repairs to exposed live parts of the
compressor electrical system.
Close and lock all access doors when the compressor
is left unattended.
Do not use extinguishers intended for Class A or Class
B fires on electrical fires. Use only extinguishers
suitable for class
BC
or class
ABC
fires.
Attempt repairs only in clean, dry, well lighted and
ventilated areas.
Connect the compressor only to electrical systems that
are compatible with its electrical characteristics and
that are within it’s rated capacity.
Condensate disposal
As waste water regulations vary by country and region
it is the responsibility of the user to establish the
limitations and regulations in their particular area.
Ingersoll–Rand and its associated distributors are
happy to advise and assist in these matters.
Oil disposal
Steps to be taken in the case of spillage: Soak up with
a suitable absorbent material, then sweep into a plastic
bag for disposal.
Burn in an approved incinerator, or according to local
area or country regulations.
For further information, consult ULTRA COOLANT