![Ingersoll-Rand NIRVANA IRN110K-OF Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/ingersoll-rand/nirvana-irn110k-of/nirvana-irn110k-of_operation-and-maintenance-manual_2059155032.webp)
8.0 GENERAL INFORMATION
IRN37–160K–OF & IRN50–200H–OF
http://air.irco.com
28
N90K
N110K
N132K
N160K
General
Sound pressure level dB(A) – AC
(3)
72–79
72–79
72–79
72–79
Sound pressure level dB(A) – WC
(3)
69–73
69–73
69–78
69–78
Maximum ambient temperature
_
C (
_
F)
46 (115)
46 (115)
46 (115)
46 (115)
Minimum ambient temperature
_
C (
_
F)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
Weight Kg (lbs)
7088
7088
7088
7088
Maximum pressure barg (psig)
10.3 (150)
10.3 (150)
10.3 (150)
10.3 (150)
Minimum pressure barg (psig)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
Coolant capacity litres (US gal)
64.4 (17)
64.4 (17)
64.4 (17)
64.4 (17)
Performance
(1)
Flow at 7.5 Barg (m
3
/min)
14.8
18.2
21.6
25.2
Flow at 8.5 Barg (m
3
/min)
13.9
17.2
20.6
24.5
Flow at 10 Barg (m
3
/min)
12.4
15.7
19.0
23.1
Flow at 100 psig (cfm)
545
664
787
903
Flow at 125 psig (cfm)
486
604
722
862
Flow at 150 psig (cfm)
426
543
658
805
Air Cooling System
Cooling air flow m
3
/min (cfm)
411 (14500)
411 (14500)
411 (14500)
411 (14500)
Maximum
∆
P in air ducts Pa (inch WG)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
Compressed air outlet
∆
T
_
C (
_
F)
(2)
11 (20)
11 (20)
11 (20)
11 (20)
Water Cooling System
Cooling (clean) water flow l/min (US gallon/min)
125 (33)
144 (38)
182 (48)
193 (51)
Cooling air flow m
3
/min (cfm)
113 (4000)
113 (4000)
113 (4000)
113 (4000)
Maximum
∆
P in air ducts Pa (inch WG)
62 (0.25)
62 (0.25)
62 (0.25)
62 (0.25)
Compressed air outlet
∆
T
_
C (
_
F)
(2)
8 (15)
8 (15)
8 (15)
8 (15)
Main Power Circuit
AC (WC)
Package full load current at 380V (A)
(1)
193 (188)
232 (222)
271 (262)
324 (314)
Package full load current at 415V (A)
(1)
183 (179)
221 (211)
257 (249)
308 (298)
Package full load current at 460V (A)
(1)
159 (156)
192 (184)
224 (216)
268 (259)
Package full load current at 575V (A)
(1)
127 (124)
154 (147)
179 (173)
214 (207)
Fuse type
(4)
Fast acting class J, T or semiconductor type, current
limiting interrupt rating 200, 000 Amps
RMS SYM.
Heater Circuit
110V Single Phase Rating (A)
1.2
1.2
1.2
1.2
230V Single Phase Rating (A)
0.6
0.6
0.6
0.6
Fuse type
General purpose
(1)
FAD (Free Air Delivery)
is actual flow rate at the compressor inlet measured at the discharge terminal point of the package in accordance with
ISO1217 Annex C.
(2)
CTD (Cold Temperature Difference) based on 100
_
F/38
_
C
inlet air at 40% relative humidity.
(3)
Sound levels are “free field conditions” per Pneurop PN8NTC2.3, +/– 3dB(A).
(4)
Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable size should be calculated on
basis of mean package full load current X1.25 (i.e. 25% margin)