Book 43212455 (11/03)
32
The life of the oil separator element is dependent
upon the operating environment (soot, dust, etc.)
and should be replaced every twelve months or
2000 hours. To replace the element proceed as
follows:
•
Ensure the tank pressure is zero.
•
Disconnect the hose from the scavenge
tube.
•
Remove scavenge tube from tank cover.
•
Disconnect service line from cover.
•
Remove cover mounting screws.
•
Remove cover and element.
•
Remove any gasket material left on cover
or tank.
•
Install new element.
NOTICE:
Do not remove staples from the
element/gasket connection.
•
Place a straightedge across top of element
and measure from bottom of straightedge to
bottom of element. (See drawing below)
•
Replace scavenge tube in cover (cover is
still off of tank).
•
Measure from bottom of cover to end of
scavenge tube. Measurement should be
from 1/8” to ¼” less than the element
measurement. If not, cut to size.
•
Remove scavenge tube.
•
Reposition cover (use care not to damage
gaskets).
•
Replace cover mounting screws:
•
Tighten in a crisscross pattern.
•
Reconnect service line. Replace
scavenge tube. Reconnect hose.
•
Close service valve. Start unit and look
for leaks.
When replacing the element, the scavenge lines,
orifice, filter and check valve should be thoroughly
cleaned and the oil changed.