Wall Unit
Installation of condensate piping
NOTICE
Do not force or bend the drain hose and verify that the end of it is not placed in water. Otherwise
it will cause leaking.
1. Connect the drain hose to the indoor unit's outgoing pipe (see Fig. A below).
2. Wrap the joint with tape (see Fig. B below).
3. Wrap the piping with insulation tape to avoid condensation (see Fig. C below).
Fig. A
Fig. B
Fig. C
Indoor unit wiring
1. Open the front panel of the indoor unit, remove the screw of the wiring cover and remove cover
(see Fig. D below).
2. Insert power connecting cable through the orifice for wiring at the rear of the indoor unit until it
leaves through the front side of the unit (see Fig. E below).
wiring cover
screw
panel
power connection
wire
cable-cross
hole
Fig. D
Fig. E
Tubería
de salida
Manguera
drenado
Tubería de salida
Manguera drenado
Cinta
Manguera
drenado
Tubo
aislante
Содержание 4MXW1609A1