3
LUBRICATION
Ingersoll-Rand No. 50
Ingersoll-Rand No. 100
Always use an air line lubricator with these tools.
We recommend the following Filter-Regulator-Lubrica-
tor (FRL) Unit:
Inside USA use FRL unit #C28-04-FKG0-28
Outside USA use FRL unit #C28-C4-FKG0
After each forty-eight hours of operation,
or as experi-
ence indicates, inject about 4 cc of the recommended
grease into the Grease Fitting (3).
INSTALLATION
SPECIFICATIONS
■
Tested in accordance with PNEUROP PN8NTC1.2
♦
Tested in accordance with ISO8662-7
•
Tested in accordance with ISO3744
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and the parts be separaed by material so that they can be recycle.
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut-Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
Model
Handle
Drive
Impacts
Recommended
Torque Range
■
Sound Level
dB (A)
♦
Vibrations
Level
Inlet
Connection
(Thread)
Minimum
Inside Ø
(Air
Hose)
I.D.
Type
in
bpm
ft
•
lb (N
•
m)
Pressure
•
Power
m/s
2
NPT
in (mm)
244A
pistol
1/2 sq.
1,300
(40-350)
(54-474)
96
109
5.5
1/4
3/8 (10)
244A-2
1/2 sq.
with
extended
anvil
(Dwg. TPD905-2)