3
PLACING TOOL IN SERVICE
LUBRICATION
Ingersoll–Rand No. 50
Ingersoll–Rand No. 100
Always use of an air line lubricator. We recommend the
following Filter–Lubricator–Regulator Unit:
For International– No. C28–C4–FKG0
For USA – No. C28–04–FKG0–28
After each forty–eight hours of operation, or as
experience indicates, inject about 4 cc of the
recommended grease into the Grease Fitting (4).
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905–1)
SPECIFICATIONS
Model
Type of
Handle
Drive
Impacts per
min.
Recommended Torque Range
in.
Forward
ft–lb (Nm)
Reverse
ft–lb (Nm)
231XP
pistol
1/2” sq.
1,150
25–300 (34–407)
25–350 (34–475)
231XP–2
pistol
1/2” sq. with
extended
anvil
1,150
25–300 (34–407)
25–350 (34–475)
231XPS
pistol
1/2” sq.
1,150
25–300 (34–407)
25–350 (34–475)
231XPS–2
pistol
1/2” sq. with
extended
anvil
1,150
25–300 (34–407)
25–350 (34–475)
Model
H
Sound Level
dB (A)
♦
Vibrations
Level
Pressure
Power
m/s
2
231XP
97.0
110
5.2
231XP–2
97.0
110
5.2
231XPS
93.7
106.7
5.2
231XPS–2
93.7
106.7
5.2
H
Tested in accordance with PNEUROP PN8NTC1.2
♦
Tested in accordance with ISO8662–7
4 Letter
Date Code
location
A __ __ __
TPD2032
231XP