EN-2
04579652_ed4
EN
Installation and Lubrication
Size air supply line to ensure tool’s maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install
a properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any
hose coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16576175 and table on page 2. Maintenance frequency is shown in
circular arrow and defined as h=hours, d=days, and m=months. Items identified as:
1. Air filter
6.
Thread size
2. Regulator
7.
Coupling
3. Lubricator
8.
Safety Air Fuse
4. Emergency shut-off valve
9.
Oil
5. Hose diameter
10. Oil - before starting, into air inlet
Note
: If the action of the tool becomes sluggish:
- Pour 3 cm
3
of cleaning solution into air inlet and run tool for 30 seconds.
- Pour 3 cm
3
of Oil into air inlet and run tool for 30 seconds.
Note
: Before storing the tool or leaving idle exceeding 24 hours:
- Pour 3 cm
3
of IR # 10 oil into air inlet and run tool for 5 seconds.
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
Original instructions are in English. Other languages are a translation of the original instructions.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest
Ingersoll Rand
Office or Distributor.