Once the injector has been replaced, it is necessary to adjust the primary air inlet to the injector by
adjusting the air adjustment tube Venturi. The adjustment distance of air A, must be placed
according to the technical date table for each gas type.
IMPORTANT:
Once all the operations for a change of gas type have been carried out, the gas indication label of the
apparatus should be corrected to indicate the new type of gas for which the machine has been prepared.
Before starting the apparatus system should be checked for gas leaks. To this end, ALL JOINTS AND ALL
PARTS THAT HAVE BEEN MANIPULATED should be covered with soapy water, foam or gas detector.
In the case of any leak being found, the mains gas supply valve should be closed and repairs effected on the
affected part. This operation should be repeated until a completely gas tight circuit is achieved.
AIR FLOW EV ACU ATION
The appliance will be installed in the places enough breezy according to the regulations in force.
According to EN 13410:2001, the air evacuation flow must consider, temporary, the air
evacuations flows required by the other ending. The surface and the orifice number are calculated
from raise value of theses air evacuation flow.
To calculate the air evacuation flow required will use the following formula:
V
tot
= ∑Q
NB
· L
Where:
V
tot
:
total air evacuation flow required in cubic meters per hour (m3/h)
∑Q
NB
: total calorific consumption of all working appliances, in Kilowatt (KW)
L:
unit air evacuation flow (
>10m3/h) Kw
C AR ACTERISTICHS PL AT E
The caracteristichs plate is placed in the back part
LUBRIC ATE V ALVES
Not lubricate the valve in any case, if it doesn’t work replace the valve.
USER OPER ATIONS AND M AINTEN ANCE INSTRUCT IONS
PR E U S E AN D M AI N T EN A N C E P R EC AU T I O N S
This appliance is for professional use only and must be used by qualified personnel.
It is suitable to call the qualified installer to install the appliance, and if it is necessary to adapt his
use to other type of gas.
To carry out the maintenance, cleaning or repair, the main gas supply stop tap must be closed.
The modifying, removal or lack of maintenance of any part of the appliance increases the risk
of accidents. It is recommended to carry out periodically checks, in accordance with the
regulations in force in the country where the appliance is to be installed.
The manufacturer accepts no responsibility for damages or injury resulting from the
modification, removal or lack of maintenance of its parts carried out without prior, express
authorization of the manufacturer.
The parts that have been manipulated by the manufacturer MUST NOT BE MANIPULATED
by the installer and/or the user.
It is very important to be careful with the hot surfaces such as griddles, front and sides, to
avoid burns.
To carry out all the cleaning and maintenance operations it is necessary to let the appliance go
cold.
AP P L I L AN C E I G N I T I O N AN D T U R N I N G O F F I N ST R U C T I O N S
Ignition:
- Open the main gas supply.
- Press and turn the knob to the burner to position small flame.
- Press the button of the piezo-electric until the flame on the burner.