INSTALLATION INSTRUCTIONS
This heater must be permanently installed and hard wired by a licensed electrician in accordance with local electrical
codes. Assembly procedure must be performed with no electrical power to unit.
Step 1:
Check UL/CUL/CE label on heater for proper voltage.
Step 2:
Follow supplied wiring instructions (see wiring instructions below).
Step 3:
Heater must be mounted with reflector angled down.
Step 4:
All electrical connections must be in compliance with the National Electric Code (NEC) and local codes for
outdoor wiring.
Step 5:
Use only wiring components UL/CUL/CE listed for outdoor use with IPX4 minimum rating.
3
1/2" NPT
If rotation is required,
push in the spring pin
located on the back
side of the heater
trim to disengage the
two pins from their
alignment hole and
rotate 180º.
Connect power with flexible
conduit or appropriate cord to
allow heater to be swiveled.
WIRING INSTRUCTIONS
The heater is drilled and threaded for standard 1/2" conduit fittings. The installing electrician will need to provide the
appropriate rigid metallic, flexible or liquid tight conduit for the installation location.
• Use only copper wire suitable for 90°C.
• Observe local electrical code regulations.
"T" slot allows the
mounting bracket
to slide for flexible
mounting options.
Logo plate (designed
to rotate if required).
TYPICAL WIRING OPTIONS
HEATING ELEMENT
OFF
ON
OFF
ON
HEATER
TOP
P L1
L2
H2
H1
HEATER
FOR 115V. PILOT
LIGHT IF USED
11/32" (0.9 CM) INSIDE NUT
SNUG TO CERAMIC
11/32" (0.9 CM) OUTSIDE NUT
REAR VIEW OF
CONTROLLER FOR
MAX. 15 AMP
LOAD ONLY
"TOP" MARKED ON
REAR OF CONTROL
MUST BE INSTALLED
IN AN UP POSITION
240 V.
240 V.
WHITE
BLACK
115
V.
TYPICAL 120V WIRING
FOR A SINGLE POLE SWITCH
TYPICAL 240V WIRING FOR
A TWO POLE SWITCH
WIRING FOR OPTIONAL 120V/240V CONTROLS