CLEARANCE FROM COMBUSTIBLES:

MIN. 18" (45.7cm) 

FROM SIDES AND  
ENDS OF HEATER

MIN. 36" (91.4cm)  

IN FRONT OF HEATER

MIN. 6" (15.2cm)  

CLEARANCE 

BEHIND HEATER

READ ALL INSTRUCTIONS BEFORE USING HEATER. Unit may be a source of possible shock. NEVER attempt to 

service heater without disconnecting its power source. Source of possible ignition.

WARNING: If not installed, operated and maintained in accordance with the manufacturer’s instructions, 

this product can expose you to chemicals including nickel, which are known to the State of California to 

cause cancer. For more information go to www.P65Warnings.ca.gov.

High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3' (0.9m) 

from the front of heater and away from sides and rear.

WARNINGS

CAUTION

MOUNTING HEIGHT/CLEARANCES

“IMPORTANT INSTRUCTIONS” 

“SAVE THESE INSTRUCTIONS”

•  

For Wall-Mounting, do not install heater closer than 

18" (45.7cm) from adjacent walls and 6" (15.2cm) 

from ceiling and do not install less than 6' (1.8m) 

if the heater is labeled as UL Listed and 8' (2.4m) 

if the heater is labeled as UL/CUL Listed from floor, 

while heater is set at a downward angle of 30 to  

60 degrees.

•  

For Ceiling-  Mounting, do not install heater closer 

than 18" (45.7cm) from adjacent walls and 6" 

(15.2cm) from ceiling and do not install less than 6' 

(1.8m) if the heater is labeled as UL Listed and 8' 

(2.4m) if the heater is labeled as UL/CUL Listed from 

floor, while heater is at a maximum 30 degrees.

•  

Adjacent Heaters to be installed no less than 3' 

(0.9m) apart.

•  

Do NOT operate within 25' (7.6m) of flammable/

explosive material.

•  

Never block heater.

•  

Heaters greater than 240 Volts are for “Commercial 

Use Only. Risk of fire. Do not use as a residential or 

household heater.”

•  

A means for disconnection of the appliance must 

be incorporated in accordance with the local wiring 

codes.

•  

Do not use if the heating element is damaged or 

cracked.

•  Not for use as a replacement for forced air/ 

ductless heating.

• Do not leave powered heaters unattended.
•  Do not run heaters for more than 4 hours at a time 

without a 15-minute cool down period between uses.

Содержание SL Series

Страница 1: ...rnings 2 Installation Instructions 3 Wiring Instructions 3 Bracket Spacing 4 Mounting Instructions 4 5 Replacement Element Installation 5 Replacement Parts 5 6 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ... 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is set at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8m if the heater is labeled as UL L...

Страница 3: ... and rotate 180º Connect power with flexible conduit or appropriate cord to allow heater to be swiveled WIRING INSTRUCTIONS The heater is drilled and threaded for standard 1 2 conduit fittings The installing electrician will need to provide the appropriate rigid metallic flexible or liquid tight conduit for the installation location Use only copper wire suitable for 90 C Observe local electrical c...

Страница 4: ...SPACING These models may be chain or bracket mounted to any ceiling or horizontal surface Installation must be such that 18 45 7cm minimum clearance is maintained around the heater on all four sides and 36 0 9m directly in front A minimum of 6 15 2cm of clearance provided by mounting brackets is required behind the plane of the face Adjustable wall ceiling brackets are furnished with all SL Series...

Страница 5: ...t to prevent damage to element Nut should be tightened snug A loose connection can cause the element to short or fail prematurely REPLACEMENT ELEMENT INSTALLATION VISIT INFRATECH USA COM FOR VIDEO INSTRUCTIONS SCAN FOR VIDEO INSTRUCTIONS Heater must be installed with the quartz tube horizontally level For maximum tube life use a level to find the optimum position for the heater s body Always maint...

Страница 6: ...se brackets may be discarded when the heater is hung with chains or other special bracketing See sales literature and price list for full listing of models descriptions amperages and voltages At times especially when the mounting height might be quite low an increased number of smaller heaters can help prevent overheating Heaters up to 15 AMPS can be controlled with a simple INF Input Regulator Th...

Страница 7: ...TING Unless heaters are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed Angle fixture 30º to 60º from horizontal face down Best angle is approximately 45º Install fixture to heat the area from the cold si...

Страница 8: ...es due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property however arising Important Please retain original proof of purchase to establish warranty period Any implied warranties of merchan...

Отзывы: