background image

REPLACEMENT PARTS

REPLACEMENT ELEMENTS

Consult back of heater for proper 
watts and voltage.

 

PART NUMBER 

PART DESCRIPTION 

QUANTITY

  13-7004, 13-7002, 13-7000 

Body Reflector Set (SL 16/24/30/40) 

1

  13-7008 

End Reflector 

2

  13-7034, 13-7032, 13-7030 

Lead Wire Set (SL 16/24/30/40) 

1

  13-7020, 13-7022 

Bracket Set (Stainless Steel, Bronze) 

1

 

13-7014, 13-7012, 13-7010 

Grill (SL 16/24/30/40) 

1

  13-7028, 13-7026, 13-7024 

Stainless Steel Trim (SL 16/24/30/40) 

1

 

PART NUMBER 

MODEL 

LENGTH 

WATTS 

VOLTS 

FITS

  10-7025 

E-1612-SL 

22-3/8" 

1600 

120 

SL-1612

  10-7030 

E-1624-SL 

22-3/8" 

1600 

240 

SL-1624

  10-7035 

E-2424-SL 

35-3/8" 

2400 

240 

SL-2424

  10-7040 

E-2428-SL 

35-3/8" 

2400 

208 

SL-2428

  10-7055 

E-3024-SL 

56-3/8" 

3000 

240 

SL-3024

  10-7060 

E-3028-SL 

56-3/8" 

3000 

208 

SL-3028

  10-7075 

E-4024-SL 

56-3/8" 

4000 

240 

SL-4024

  10-7080 

E-4028-SL 

56-3/8" 

4000 

208 

SL-4028

Need help? 

To order replacement 

elements for your Infratech 

heating system, please contact 

us via phone or visit the auto-

motive section of our website.

PROBLEM

 

Heater does not glow

Low heat output

Heater does not work

WHAT TO DO

Check supply voltage to confirm it matches voltage of heating element.

A 240 V element connected to 110 V or 208 V will warm, but not glow orange, or 
generate sufficient heat for typical applications. (Matching your Voltage is extremely 
important). 
If element is visibly orange, but there is insufficient heat, refer to the areas covered, 
with respect to conditions and mounting heights.  
Replace or clean dirty or non reflective reflectors.

Disconnect power and check element with Ohm meter for continuity.  If there is any 
continuity across the bulb, the problem is in the wiring/controls. 
Check that there is proper voltage to the heater. 
Check that the control/switch is working.  
Check main power circuit breaker. 
Check wiring for a loose connection or burned wire.

TROUBLESHOOTING

6

Содержание SL 16XX series

Страница 1: ...lation Instructions 3 Wiring Instructions 3 Outdoor Installation 3 Maintenance Instructions 3 APPLICATION INFORMATION Mounting Instructions 3 4 Typical Wiring Schematics 4 General Notes 5 Areas Covered Table 5 Location Suggestions 7 PARTS LIST Parts List 6 Trouble Shooting Guide 6 Warranty 8 Warranty Registration 8 SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8 m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to be installed no less than 3 0 9 m apart Do NOT ope...

Страница 3: ...k UL CE label on heater for proper voltage Step 2 Follow supplied wiring instructions The heater is drilled and threaded for standard 1 2 conduit fittings The installing electrician will need to provide the appropriate rigid metallic flexible or liquid tight conduit for the installation location Use only copper wire suitable for 90 C Observe local electrical code regulations Step 1 Heater must be ...

Страница 4: ...S HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CONTROLLER FOR MAX 15 AMF LOAD ONLY TOP MARKED ON REAR OF CONTROL MUST BE INSTALLED IN AN UP POSITION 240 V 240 V WHITE BLACK 115 V TYPICAL 120V WIRING FOR A SINGLE POLE SWITCH TYPICAL 240V WIRING FOR A TWO POLE SWITCH WIRING FOR OPTIONAL 120V...

Страница 5: ...st solution is to heat from two sides rather than from just one side However there are times when this is not practical 5 Areas covered are approximate dimensions and will vary depending on prevailing conditions and personal comfort levels 5 HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CON...

Страница 6: ...8 SL 4028 Needhelp Toorderreplacement elements for your Infratech heating system please contact us via phone or visit the auto motive section of our website PROBLEM Heater does not glow Low heat output Heater does not work WHAT TO DO Check supply voltage to confirm it matches voltage of heating element A 240 V element connected to 110 V or 208 V will warm but not glow orange or generate sufficient...

Страница 7: ... heat Warmer air rises from floor Some heat reflects from floor Mounting a heater directly over a table or other obstruction will block the energy primarily heating the object It is best to move heater to the side allowing complete body and floor coverage When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it will last l...

Страница 8: ...ant safety related product information The information will not be sold or used for any marketing related purposes Warranty Limitations and Exclusions This warranty does not apply to damages resulting from negligence alteration misuse abuse accident natural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh c...

Отзывы: