NOTE: DO NOT mount the heater on a vertical axis. Such installation will reduce the life of the element and will
automatically void the product’s warranty. Heater must be installed with the quartz tube horizontally level. For maximum
tube life, use a level to find the optimum position for the heater’s body. Always maintain the minimum clearances from
the heater body to any combustible materials.
18"
SIDE
18"
END
72"
BELOW
7"
LEVEL HERE
1/2" NPT
4
TYPICAL WIRING OPTIONS
HEATING ELEMENT
OFF
ON
OFF
ON
HEATER
TOP
P L1
L2
H2
H1
HEATER
FOR 115V. PILOT
LIGHT IF USED
11/32" INSIDE NUT
SNUG TO CERAMIC
11/32" OUTSIDE NUT
REAR VIEW OF
CONTROLLER FOR
MAX. 15 AMF
LOAD ONLY
"TOP" MARKED ON
REAR OF CONTROL
MUST BE INSTALLED
IN AN UP POSITION
240 V.
240 V.
WHITE
BLACK
115 V
.
TYPICAL 120V WIRING
FOR A SINGLE POLE SWITCH
TYPICAL 240V WIRING FOR
A TWO POLE SWITCH
WIRING FOR OPTIONAL 120V/240V CONTROLS
Heater can also be hung in a horizontal position using chains or
custom brackets. Heater must be level, but can be rotated around
its horizontal axle.
MODEL
MINIMUM SPACING BETWEEN BRACKETS
SL 16XX
12"
SL 24XX
20"
SL 30XX
30"
SL 40XX
30"
BRACKET SPACING