WARNINGS

CAUTION

MOUNTING HEIGHT/CLEARANCES

READ ALL INSTRUCTIONS BEFORE USING HEATER
Unit may be a source of possible shock. NEVER attempt to service heater without disconnecting its power source.
Source of possible ignition.

High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3 feet 
(0.9m) from the front of heater and away from sides and rear.

CLEARANCE FROM COMBUSTIBLES:

·  For Wall-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm) from 

ceiling and do not install less than 6' (1.8 m) if the heater is labeled as UL Listed and 8' (2.4m) if the heater is 
labeled as UL/CUL Listed from floor, while heater is set at a downward angle of 30 to 60 degrees.

·  For Ceiling-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm) from 

ceiling and do not install less than 6' (1.8 m) if the heater is labeled as UL Listed and 8' (2.4m) if the heater is 
labeled as UL/CUL Listed from floor, while heater is at a maximum 30 degrees.

· Adjacent Heaters to be installed no less than 3' (0.9 m) apart.

· Do NOT operate within 25 feet of flammable/explosive material.

· Never block heater.

·  Heaters greater than 240 Volts are for “Commercial Use Only. Risk of fire. Do not use as a residential or 

household heater.”

· A means for disconnection of the appliance must be incorporated in accordance with the local wiring codes.

· Do not use if the heating element is damaged or cracked.

MIN. 6" CLEARANCE 
BEHIND HEATER

MIN. 36" IN FRONT 
OF HEATER

MIN. 18" FROM 
SIDES AND ENDS 
OF HEATER

“IMPORTANT INSTRUCTIONS”

“SAVE THESE INSTRUCTIONS”

Содержание SL 16XX series

Страница 1: ...lation Instructions 3 Wiring Instructions 3 Outdoor Installation 3 Maintenance Instructions 3 APPLICATION INFORMATION Mounting Instructions 3 4 Typical Wiring Schematics 4 General Notes 5 Areas Covered Table 5 Location Suggestions 7 PARTS LIST Parts List 6 Trouble Shooting Guide 6 Warranty 8 Warranty Registration 8 SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8 m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to be installed no less than 3 0 9 m apart Do NOT ope...

Страница 3: ...k UL CE label on heater for proper voltage Step 2 Follow supplied wiring instructions The heater is drilled and threaded for standard 1 2 conduit fittings The installing electrician will need to provide the appropriate rigid metallic flexible or liquid tight conduit for the installation location Use only copper wire suitable for 90 C Observe local electrical code regulations Step 1 Heater must be ...

Страница 4: ...S HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CONTROLLER FOR MAX 15 AMF LOAD ONLY TOP MARKED ON REAR OF CONTROL MUST BE INSTALLED IN AN UP POSITION 240 V 240 V WHITE BLACK 115 V TYPICAL 120V WIRING FOR A SINGLE POLE SWITCH TYPICAL 240V WIRING FOR A TWO POLE SWITCH WIRING FOR OPTIONAL 120V...

Страница 5: ...st solution is to heat from two sides rather than from just one side However there are times when this is not practical 5 Areas covered are approximate dimensions and will vary depending on prevailing conditions and personal comfort levels 5 HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CON...

Страница 6: ...8 SL 4028 Needhelp Toorderreplacement elements for your Infratech heating system please contact us via phone or visit the auto motive section of our website PROBLEM Heater does not glow Low heat output Heater does not work WHAT TO DO Check supply voltage to confirm it matches voltage of heating element A 240 V element connected to 110 V or 208 V will warm but not glow orange or generate sufficient...

Страница 7: ... heat Warmer air rises from floor Some heat reflects from floor Mounting a heater directly over a table or other obstruction will block the energy primarily heating the object It is best to move heater to the side allowing complete body and floor coverage When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it will last l...

Страница 8: ...ant safety related product information The information will not be sold or used for any marketing related purposes Warranty Limitations and Exclusions This warranty does not apply to damages resulting from negligence alteration misuse abuse accident natural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh c...

Отзывы: