background image

MOUNTING INSTRUCTIONS

These models may be chain or bracket mounted to any ceiling or horizontal surface. Installation must be such that 18" 
minimum clearance is maintained around the heater on 4 sides and 36" directly in front. 6" of clearance provided by 
mounting brackets is required behind the plane of the face.

Adjustable wall/ceiling brackets are furnished with all SL-series heaters. Brackets have positive stops at 30°and 60°. 
When used, they allow heater to be fastened to wall and then tipped down to 60°; for ceiling mount, tilted to 30° max. 
Brackets are positioned along a “T” slot on back of unit. You must maintain a minimum distance between the mounting 
brackets to ensure a stable installation.

“T” SLOT

INSTALLATION INSTRUCTIONS

WIRING INSTRUCTIONS

OUTDOOR INSTALLATION

This heater must be permanently installed and hard wired by a licensed electrician in accordance with local electrical 
codes. Assembly procedure must be performed with no electrical power to unit.

Step 1:

 Check UL/CE label on heater for proper voltage.

Step 2:

 Follow supplied wiring instructions

The heater is drilled and threaded for standard 1/2" conduit fittings. The installing electrician will need to provide the 
appropriate rigid metallic, flexible or liquid tight conduit for the installation location.
Use only copper wire suitable for 90°C.
Observe local electrical code regulations.

Step 1:

 Heater must be mounted with reflector angled down.

Step 2:

 All electrical connections must be in compliance with the National Electric Code and local codes for outdoor wiring.

Step 3:

 Use only wiring components UL/CE listed for outdoor use with IP X 4 minimum rating.

MAINTENANCE INSTRUCTIONS

Before performing any maintenance, power must be disconnected and the heater cool to touch.
Heater housing, reflector and heating element can be rinsed with a hose or wiped down with isopropyl alcohol, acetone, 
or glass cleaner, using a clean, scratch-free rag or paper towel. Any oxidation, surface rust or discoloration can be 
removed with stainless steel cleaner or metal polish on the bare metal surface.
Make sure all water, solvents or cleaners are removed and the heater is dry before reconnecting power.

3

Содержание SL 16XX series

Страница 1: ...lation Instructions 3 Wiring Instructions 3 Outdoor Installation 3 Maintenance Instructions 3 APPLICATION INFORMATION Mounting Instructions 3 4 Typical Wiring Schematics 4 General Notes 5 Areas Covered Table 5 Location Suggestions 7 PARTS LIST Parts List 6 Trouble Shooting Guide 6 Warranty 8 Warranty Registration 8 SAVE THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...at a downward angle of 30 to 60 degrees For Ceiling Mounting do not install heater closer than 18 45 7cm from adjacent walls and 6 15 2cm from ceiling and do not install less than 6 1 8 m if the heater is labeled as UL Listed and 8 2 4m if the heater is labeled as UL CUL Listed from floor while heater is at a maximum 30 degrees Adjacent Heaters to be installed no less than 3 0 9 m apart Do NOT ope...

Страница 3: ...k UL CE label on heater for proper voltage Step 2 Follow supplied wiring instructions The heater is drilled and threaded for standard 1 2 conduit fittings The installing electrician will need to provide the appropriate rigid metallic flexible or liquid tight conduit for the installation location Use only copper wire suitable for 90 C Observe local electrical code regulations Step 1 Heater must be ...

Страница 4: ...S HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CONTROLLER FOR MAX 15 AMF LOAD ONLY TOP MARKED ON REAR OF CONTROL MUST BE INSTALLED IN AN UP POSITION 240 V 240 V WHITE BLACK 115 V TYPICAL 120V WIRING FOR A SINGLE POLE SWITCH TYPICAL 240V WIRING FOR A TWO POLE SWITCH WIRING FOR OPTIONAL 120V...

Страница 5: ...st solution is to heat from two sides rather than from just one side However there are times when this is not practical 5 Areas covered are approximate dimensions and will vary depending on prevailing conditions and personal comfort levels 5 HEATING ELEMENT OFF ON OFF ON HEATER TOP P L1 L2 H2 H1 HEATER FOR 115V PILOT LIGHT IF USED 11 32 INSIDE NUT SNUG TO CERAMIC 11 32 OUTSIDE NUT REAR VIEW OF CON...

Страница 6: ...8 SL 4028 Needhelp Toorderreplacement elements for your Infratech heating system please contact us via phone or visit the auto motive section of our website PROBLEM Heater does not glow Low heat output Heater does not work WHAT TO DO Check supply voltage to confirm it matches voltage of heating element A 240 V element connected to 110 V or 208 V will warm but not glow orange or generate sufficient...

Страница 7: ... heat Warmer air rises from floor Some heat reflects from floor Mounting a heater directly over a table or other obstruction will block the energy primarily heating the object It is best to move heater to the side allowing complete body and floor coverage When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it will last l...

Страница 8: ...ant safety related product information The information will not be sold or used for any marketing related purposes Warranty Limitations and Exclusions This warranty does not apply to damages resulting from negligence alteration misuse abuse accident natural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh c...

Отзывы: