1.3 TERMINAL SETUP
The Terminal is attached to the top DB-25 connector on the back side of the marker using
the supplied cable. The terminal facilitates the interface between the user and the marker. A
terminal or terminal program is required. The Terminal settings should be:
Emulation
--
VT220
Keyboard Type
--
108
Main Port Speed
--
19200
Data Width
--
8
Parity
--
None
Stop
--
1
Transmit Flow Control
--
X-ON / X-OFF
Receive Flow Control
--
X-ON / X-OFF
Host Interface
--
RS232
If a terminal was supplied with the KE28XX to enter or exit the terminal settings screen
press SHIFT-F3. To check correct settings on the terminal, power on the marker by
switching the key switch located on front panel to the ON position. The software contained
within the marker should present the user with a bordered windowed screen.
1.4 COMMON PRINTER SETTINGS FOR VARIOUS MODELS
Printer Model
KE2800
KE2856/54
KE2852/53
Heat: (4:1)
10
50
150
Stepper Resolution
0.00505
0.00505
0.0103
Stepper Delay
150
450
600
Mirror Resolution
0.006
0.006
0.012627
Reverse Take-up
1
1
1
Laser Off Tickle
7
7
7
Tear Off Location
7
7/ Application
Dependent
7 / Application
Dependent
Cache
ON[X]
ON[X]
ON[X]
High Definition
ON[X]
ON[X]
OFF [ ]
Number of Lasers
1
2
2
Pixels Per Row
560
560
280
Galvo Divider
5
5
10