12
2-4 Input Wiring Diagram
1.NPN photoelectric sensor wiring
;
The equipment defaults to the initial logic. The photoelectric sensor shall be NPN type,
and the photoelectric sensor shall be connected to signal terminals 1, 2 and 3. The
corresponding line sequence is shown in the table:
Photoelectric sensor
Terminal
+(L+)
1
(
DC24V
)
-(M)
2
(
GND
)
¬Q
3
(
IN1
)
Note: The high level voltage of input terminal is ranged from 5v to 24v
。
2.Switch connection
;
The switch connection defaults to the initial logic. Connecting the switch to signal
terminals 2 and 3, and when the switch is pressed, the trigger takes effect. The line
sequence is shown in the table below
:
3.Relay trigger wiring
;
The equipment defaults to the initial logic and the relay is connected to signal terminals 2
and 3. When the rated voltage is applied, the trigger takes effect. The corresponding line
sequence is shown in the table below
:
Push button switch
Terminal
SW1
2
(
GND
)
SW2
3
(
IN1
)
Relay
Terminal
Open node 1
2
(
GND
)
Open node 2
3
(
IN1
)