background image

11

Note

: It depends on the voltage of the power supply connected to the serial port cable.

Note

: The effective level value can be set, and the default is 24VDC.

Serial

number

Terminal

name

Describe

Remarks

1

24V

Power input / output

Power output: it can supply power to external

equipment (note

) power input: it can be connected

to 20-30v for power supply

2

GND

GND

GND

3

IN1

Input signal 1

Logic level ( The default low level takes effect )

4

IN2

Input signal 2

Logic level ( The default low level takes effect )

5

GND

GND

GND

6

COM-IN

Voltage output (+)

It forms voltage feedback with out1-out2,

5V \ 24V \ external voltage (no more than 36VDC)

7

OUT1

Transistor output 1

Optional internal pull-up and effective level (note

)

8

OUT2

Transistor output 2

Optional internal pull-up and effective level (note

)

9

NC

10

NC

11

NC

12

GND

GND

GND

13

GND

GND

GND

14

24V

Power input / output

Power output: it can supply power to external

equipment (note

) power input: it can be connected

to 20-30v for power supply

Содержание FV5X

Страница 1: ...infoscan FV5X Operating Manual NANJING BILIN INTELLIGENT IDENTIFICATION TECHNOLOGY CO LTD www infoscan com cn Tel 400 700 6288 Ver 20220426...

Страница 2: ...ng FV5X to infostepper 19 4 2 1 RS 232 Connection 19 4 2 2 Ethernet TCP IP Connection 20 4 2 3 USB Connection 21 5 How to quickly Setup FV5X without infostepper 22 6 How to Set up FV5X with infosteppe...

Страница 3: ...ing the Prefix or Suffix 45 7 4 the Logic Diagram of IO Output 47 7 5 How to read a color reversed barcode 48 7 6 How to Read Dot matrix Barcode 49 7 7 How to Read Small sized or Defaced DM Barcode 50...

Страница 4: ...Process 1 Check packaging materials 2 Wiring and installation 3 Connecting the power adapter 4 Connecting FV5X to computer and running the infostepper 5 Briefly setting up FV53 6 Detailed setting and...

Страница 5: ...1 Unwrapping the Package 1 1 Scanner and its belonging Model Name Package content Quantity Picture FV53 Industrial scanner Scanner 1 Quick Use Guide 1 Installation plate 1 Insulating gasket 1 Screws...

Страница 6: ...r to the customer s actual order for product accessories Name Package content Model Quantity Picture Cable Serial communication cable H12S 0 85M USBD9P F14 V1 1 Ethernet communication cable H8S 2M RJ...

Страница 7: ...indicator bule 5 Non polarization 6 Polarization 7 12 PIN Aviation jack Serial communication power supply I O 8 8 PIN Aviation jack Ethernet 9 Trigger button 10 CIR2 Custom 11 G F Reading success ind...

Страница 8: ...8 1 4 Scanner Configuration Setting up configurations Data communication Ethernet USB RS322 Ethernet I O USB...

Страница 9: ...minals 12 cores and 8 cores Be sure to connect accurately 2 Rotate the aviation plug male screw clockwise to fix it 3 After the aviation cable plug male is firmly connected with FV5X then the serial c...

Страница 10: ...he I O terminal is located on the serial communication cable If the equipment is connected to external signals or to drive external equipment it is necessary to use this terminal to connect with exter...

Страница 11: ...gic level The default low level takes effect 4 IN2 Input signal 2 Logic level The default low level takes effect 5 GND GND GND 6 COM IN Voltage output It forms voltage feedback with out1 out2 5V 24V e...

Страница 12: ...ranged from 5v to 24v 2 Switch connection The switch connection defaults to the initial logic Connecting the switch to signal terminals 2 and 3 and when the switch is pressed the trigger takes effect...

Страница 13: ...d the alarm sounds The corresponding table of line sequence is as follows Note The standard working current of output load is 350mA and the maximum working current is 400mA 2 External load relay feedb...

Страница 14: ...emale connecting the adapter output end to the power supply interface of cable DB9 2 Terminal power supply wiring Power supply can be wired in via serial port communication cable 14pin terminal strip...

Страница 15: ...whether the light source of the code reader is blocked If the light source is blocked the barcode may not be detected If there are other devices emitting strong light direct light and reflected light...

Страница 16: ...16 3 3 Angle Adjustment As shown in the figure adjusting the angle of the equipment to the appropriate angle position and fixing the L shape firmly with screws 3 4 Product Dimensions Unit mm...

Страница 17: ...10bit 28 220 60 200 35 250 10mil Code 128 10bit 28 260 45 235 35 330 15mil Code 128 10bit 35 339 50 270 60 400 20mil Code 128 10bit 45 430 60 310 80 500 5mil DataMatrix 10bit 57 85 88 120 35 70 6 67mi...

Страница 18: ...ng FV53 to infostepper 4 1 Introduction to infostepper Serial number Instruction 1 Common Toolbar 2 Connection mode and information display 3 Online feedback information display 4 Once online set the...

Страница 19: ...e window will pop up selecting Serial Port Settings then click Port Number Select the corresponding COM number below If the COM number is not displayed you can click the Refresh button to search the b...

Страница 20: ...e select Ethernet Settings select the computer network card and click Search Device as shown in the figure Click Connect to device after the connection is successful the device will have a buzzer prom...

Страница 21: ...emise of installing the USB serial port driver click Connect when connecting to the software then the Device connection window will pop up select Serial Port Settings select the corresponding COM Numb...

Страница 22: ...r adjustment process The success or failure of auto focus and auto tuning are indicated by buzzer and indicator light The success of automatic parameter adjustment is closely related to the quality of...

Страница 23: ...snap 3 In the main window of Image you can view the captured images The sample captured image is blurry which affects decoding then the focus parameters of the code reader need to be adjusted Display...

Страница 24: ...us is successful enter the continuous viewing mode directly As shown in the example the barcode area of the image is blurred before auto focusing After successful auto focusing the barcode area of the...

Страница 25: ...ss will also change significantly the image contrast will change significantly For static barcode reading applications the exposure time has little effect on the reading success rate if the mobile rea...

Страница 26: ...cording to requirements Take the baud rate setting as an example set the baud rate to 9600 select 9600 and click the OK button 3 Click Download Configuration if the setting is successful the barcode r...

Страница 27: ...The selected Parity setting appears in the setting list just click Download Configuration 5 select Data bits Stop bits according to your needs then click the OK button The selected Data bits Stop bit...

Страница 28: ...e the IP address can be directly entered by keyboard according to requirements 3 After the IP address input is completed click the Confirm button the set IP address will be displayed in the list click...

Страница 29: ...2 IO output logic OUT1 OUT2 output level signals are all 24V 3 The default IO output logic OUT1 is success OUT2 is failure the output level signal pulse width of reading success and reading failure a...

Страница 30: ...plete the setting 6 8 Setting the Buzzer and Laser Aiming Function while Good or Failure Reading 1 When the FV5X code reader succeeds or fail in reading the code the buzzer and the laser aiming functi...

Страница 31: ...4646 2 Set the trigger command for example set LON as the trigger command select Transformation Assistant and input LON to convert LON to the corresponding hexadecimal 3 Copy the Hex content converted...

Страница 32: ...ailure feedback is closed by default 2 The read failure feedback switch is set to on and the read failure character feedback character hex is set to NoRead Use the conversion assistant to convert NoRe...

Страница 33: ...reading function is off by default and rereading time is 0 S by default 2 FV5X barcode reader repeat barcode reading is set active repeat reading delay time is set to 5 3 The repetition reading time...

Страница 34: ...barcode screening function which can be set according to the code system the number of characters special characters etc to achieve screening 2 For example if the output code system is QR barcode the...

Страница 35: ...r the inductive reading mode is off by default 2 If the induction trigger is set to open you can set the induction trigger lighting intensity induction pause time grayscale frame moving speed etc 3 Th...

Страница 36: ...be selected 2 The startup mode of continuous trigger mode is divided into boot startup and I O trigger The default is I O trigger 3 Continuous trigger mode shooting interval time The default value is...

Страница 37: ...ximum amount of light entering The default value is 50 and the value range is 0 100 which can be adjusted according to actual application requirements 2 Automatic parameter adjustment speed The defaul...

Страница 38: ...ter checking click the download you can open all code system Full code system off After checking click the download you can turn off all code systems A code symbology can be turned on or off separatel...

Страница 39: ...age window obtain you can view the latest image successfully decoding image and failed decoding image set Last Image The last image taken by the reader success failure Decoding success image last time...

Страница 40: ...some download items with successful settings click Generate configuration barcode 2 According to the prompt it can be pasted into the word file or viewed in the image window the picture is viewed in t...

Страница 41: ...In the setting window click to save the current device configuration to the local storage 2 Click Open Device Configuration and select the corresponding configuration file then the parameters of the s...

Страница 42: ...2 Open Multi Barcode rules you can set multiple barcode rules Number of barcodes read The number of read barcodes can be set according to specific application requirements When the quantity is set to...

Страница 43: ...output barcodes currently in the output sequence Pull the multi barcode rule window to one side and check the mouse box in Image Decoding After selecting the box with the mouse selection function the...

Страница 44: ...de system matching you can choose different code systems one of the barcode rules Barcode length According to application requirements you can choose different lengths of barcodes one of the barcode r...

Страница 45: ...s after the prefix and suffix The input text is in hexadecimal which can be converted by the conversion assistant If you want to add ABC characters before and after the barcode open the conversion ass...

Страница 46: ...n the barcode editor Confirm compile write As shown in the figure the barcode information prefix and suffix are ABC In the multi barcode mode suffixes can also be added to multiple different barcodes...

Страница 47: ...O Output Open I O programming Save save the current I O logic Open Open I O logic Compile Write The modified I O logic needs to be clicked to compile then it will take effect after writing Load Initia...

Страница 48: ...48 7 5 How to read a color reversed barcode In the settings Decoding settings turn on the Inversed barcode reading and set the download Inversed barcode reading close Inversed barcode reading open...

Страница 49: ...9 7 6 How to Read Dot matrix Barcode In the settings Decoding settings turn on the Dot matrix code optimization and set the download Dot matirx code optimization close Dot matirx code optimization ope...

Страница 50: ...sized or Defaced DM Barcode Small DM reading optimization In the settings Decoding settings turn on the Small DM reading optimization and set the download Small DM reading optimization close Small DM...

Страница 51: ...efaced DM reading optimization In the settings Decoding settings turn on the Defaced DM reading optimization and set the download Defaced DM reading optimization close Defaced DM reading optimization...

Страница 52: ...sets of parameters can be set When setting you need to confirm the setting of the corresponding imaging parameter group The parameter group is 1 4 The default is a set of parameter groups that is the...

Страница 53: ...8 Other settings 8 1 To View Decoded Data after Settings In the data window after the device is triggered if the decoding is successful the barcode information will be displayed As shown in the figur...

Страница 54: ...ommand to trigger the device The device trigger command is TON by default and the cancel trigger command is TOFF The command trigger interval can be set and the timing setting needs to be checked The...

Страница 55: ...the baud rate is set to 9600 and the download can be set Data output is keyboard input and data can be viewed in a text file English mode Note QHQ line is optional if needed please consult with our sa...

Страница 56: ...56 8 4 How to Check the Reader Firmware Version Information Click the Help button and click Equipment Information to view the current device model firmware version number etc...

Страница 57: ...t the Scanner to Factory default Settings Click the Restore Default Layout button click the OK After hearing the device beep and seeing the success message the device has been restored to the factory...

Страница 58: ...58 8 6 How to convert characters to Hex code Click the Transformation assistant enter the required characters it will be automatically converted to hexadecimal copy the content and paste it...