background image

EonStor CS Installation Guide 

 

 

page  50  /  97

 

 

 

Installation Guide 

 

 

To edit Service Manager settings: 

a.  Click 

Service Manager settings

b.  Enable Service Manager with the toggle.   

c.  Fill in your contact information (Email, country, etc.). 

 

d.  Check 

I agree to automatically notify Infortrend when critical events occur.

 The system 

will automatically create a support ticket to Infortrend Service Center when any critical errors 

occur.

 

e. 

Check 

I agree the requests from Infortrend support engineers to transmit system 

information for troubleshooting

. Upon request, the system will send out relevant 

information (i.e., logs, system configurations, and core dumps) for diagnosis to Infortrend and 

Содержание EonStor GS 5000

Страница 1: ...ides the procedure of setting up EonStor GS GSe GSe Pro GSa and GSc family storage Hardware and software initial setup will be step by step introduced Version 1 00 Updated February 2020 EonStor GS Ins...

Страница 2: ...Installation 15 1 2 1 For 1U model 15 1 2 2 For 2U 3U 4U model 20 1 3 Install Drive on Trays 22 1 3 1 3 5 and 2 5 Drive Tray Model 2U12 2U24 3U16 4U24 22 1 3 2 2 5 Drive Tray Model 2U25 25 1 3 3 3 5...

Страница 3: ...ls 57 4 1 2 Create Volume 61 4 1 3 Mapping 63 4 2 File Level 66 4 2 1 Create Pools 66 4 2 2 Create Volume 70 4 2 3 Add Share Folder s 72 4 2 4 Create User s and User group s 74 4 2 5 Set up the Folder...

Страница 4: ...re going to deploying EonStor GS GSe GSe Pro GSa and GSc family storage this guide can help you build up the system with step by step tutorial In this guide we separate into several chapters Enclosure...

Страница 5: ...EonStor CS Installation Guide page 5 97 Installation Guide Audience This guide is intended for the Infortrend partners customers and employees who are going to building up EonStor GS...

Страница 6: ...how to connect management network and data ports for data transmission Storage Initialization 3 Storage Initialization Outline of the process of GS initialization with EonOne Setup Wizard 4 Connect wi...

Страница 7: ...ling the GS into the rack including slide rail and GS installation 1 3 Install Drive on Trays Based on different GS models outline of the process of how to install a drive on the tray 1 4 JBOD Connect...

Страница 8: ...n Guide 1 1 Check in Box Before installing the storage system make sure you have received the items listed below in your package box 1 1 1 For Desktop Models GSe Pro 100 200 Item Picture 1 Drive trays...

Страница 9: ...97 Installation Guide Power cord Quick configuration guide Quick Installation Guide Unpacking list and China RoHS compliance documentation EonOne CD Software CD 3 5 inch HDD screws 2 5 inch HDD screws...

Страница 10: ...r 2U24 2U25 2U12 3U16 4U24 4U60 bay form factor models Item Picture 1 Unpacking list and China RoHS compliance documentation 2 Rackmount kit 3 Tray EPE 4 Power cord cable and accessory boxes 5 Host bo...

Страница 11: ...page 11 97 Installation Guide 2 5 3 5 HDD tray Host Board Box Content Optional Host Board optional Power Cord Cable and Accessory Boxes Power cord Power cord clamp set Quick Installation Guide RS 232C...

Страница 12: ...EonStor CS Installation Guide page 12 97 Installation Guide EonOne CD 2 5 3 5 HDD screws Mounting enclosure screws and nuts...

Страница 13: ...1 1 3 For 4U form factor models Item Picture 1 Unpacking list and China RoHS compliance documentation 2 Rackmount kit 3 Power cord cable and accessory boxes 4 Enclosure chassis Power Cord Cable and Ac...

Страница 14: ...stallation Guide Quick Installation Guide Quick configuration guide Software CD 2 5 3 5 HDD screws Note For models that are not listed here please refer to the Unpacking list document and see the comp...

Страница 15: ...is GSe Pro 100 200 tower model 1 2 1 For 1U model Checking the contents of the slide rail kit Item Description Quantity 01 Left front bracket 1 02 Right front bracket 1 03 Rear bracket 2 04 Bracket s...

Страница 16: ...ble the slide rail 03 by inserting the rear bracket into the ditch marked with a blue oblong of the left and right front brackets 01 and 02 2 Determine where the slide rail 03 is going to be installed...

Страница 17: ...ont bracket with one M5 x 55 mm position screw 05 to the front rack post and two M5 x 55 mm position screws 05 to the rear rack post top and bottom 4 To secure the slide rail s length in place attach...

Страница 18: ...age nut secures the enclosure in place 6 Open the covers from the left and right ears of the enclosure then lift the enclosure and align it with the slide rails on the rack keeping the pressure even o...

Страница 19: ...EonStor CS Installation Guide page 19 97 Installation Guide enclosure s chassis ears to secure the enclosure to the rack...

Страница 20: ...rear rack posts then insert the cage nuts into the designated holes of the front rack posts Note If the rack does not require M5 cage nuts and has its own screw threads use the M6 or No 10 32 screws...

Страница 21: ...of the enclosure using the no 6 32 flathead screws 4 With the assistance of another person lift and insert the enclosure onto the slide rails Ensure that the inner glides on both sides of the enclosu...

Страница 22: ...ay Model 2U12 2U24 3U16 4U24 Press the release button to open the spring handle Orient the hard drive to the tray with the interface connectors facing the open side of the tray and the label is facing...

Страница 23: ...ation Guide page 23 97 Installation Guide 2 5 SAS NL SAS SATA drive Type 1 Screws from the bottom side Type 2 Screws on tray s sides Insert the assembled hard drive and tray to the enclosure with the...

Страница 24: ...EonStor CS Installation Guide page 24 97 Installation Guide Close the spring handle when the drive is fully inserted to the bay IMPORTANT The system should be full of drives...

Страница 25: ...de 1 3 2 2 5 Drive Tray Model 2U25 Press the release button to open the spring handle Place the hard drive on the tray A then secure the clips to both sides of the tray B Insert the assembled hard dri...

Страница 26: ...EonStor CS Installation Guide page 26 97 Installation Guide Close the spring handle when the drive is fully inserted to the bay IMPORTANT Hard drives are installed in all drive slots of the systems...

Страница 27: ...top Model GSe pro 100 200 Press the release button to open the spring handle A then gently pull out the tray B Orient and place the hard drive to the tray with the interface connectors facing the open...

Страница 28: ...le after the drive is fully inserted to the bay Once all drives are installed the system recognizes the disk drives and scans them automatically when powered on IMPORTANT Ensure that your system has a...

Страница 29: ...port please refer to the Expansion Enclosure Guide for more information 1 4 1 For GSe Pro 100 200 series Installing a expansion board on the unit for expansion connection 1 Facing the rear panel remov...

Страница 30: ...EonStor CS Installation Guide page 30 97 Installation Guide 3 Turn the host expansion board s knobs clockwise to secure the expansion board to the system...

Страница 31: ...EonStor CS Installation Guide page 31 97 Installation Guide Connect the expansion systems using the installed 12Gb s SAS expansion board...

Страница 32: ...stalling a new host board you will need to remove the screws holding the dummy covers in place 3 By holding onto the edges of the PCB and using the guide pin for positioning power the expansion host b...

Страница 33: ...EonStor CS Installation Guide page 33 97 Installation Guide 5 Secure the controller by fastening the two retention screws 1 under the ejection levers 2...

Страница 34: ...EonStor CS Installation Guide page 34 97 Installation Guide Connect the expansion systems using the installed 12Gb s SAS expansion board...

Страница 35: ...EonStor CS Installation Guide page 35 97 Installation Guide...

Страница 36: ...CS Installation Guide page 36 97 Installation Guide 1 4 3 For GS GSe GSa GSc 2U 3U 4U form factor series Please refer to the Expansion Enclosure Guide Expansion Enclosure Connection part for more info...

Страница 37: ...attached on slot 9 and 10 you can skip this step and go to the step connecting expansion system 1 Shut down your system and disconnect the cables from the ports on the rear panel 2 Remove the front c...

Страница 38: ...a screw IMPORTANT If you are using only one SAS expansion host board you must install it to the host board s slot 10 This slot is located on the rightmost side of the controller 6 Install back the co...

Страница 39: ...on Guide Connecting expansion systems Connecting dual controller expansions IMPORTANT To ensure redundancy a dual controller SAS expansion must be connected to the opposite ends of the expansions rst...

Страница 40: ...ont panel LED the system works normally with and remaining green GS front panel LED Number LED Name Service Power Cooling Module status Temperature status System fault The following table shows the st...

Страница 41: ...EonStor CS Installation Guide page 41 97 Installation Guide Number LED Name System status Fan Temperature status...

Страница 42: ...on Introduces the GS network architecture topology how to connect management network and data ports for data transmission Contents 2 1 Network Overview Introduces the GS network architecture topology...

Страница 43: ...is the default management port You may refer to Detailed front and back product views on official website access to link below image https www infortrend com global products families gsepro pro100 GS...

Страница 44: ...on official website access to link below image GS 5000 https www infortrend com global products families gs 5000 GSa 5000 https www infortrend com global products families gsa 5000 GSc 5000 https www...

Страница 45: ...ge EonOne Initialization wizard will pop up automatically for the GS initialization Initial Setup Wizard is a quick configuration flow that allows users to set up all the necessary configurations of t...

Страница 46: ...latest To do so click Browse and select the firmware installation file Then click Update The process may take several minutes to finish Once it is done click Next 3 Under Event Notice you can edit Not...

Страница 47: ...pport Department accordingly To edit notification settings a Click Notification settings b Go to the Email page c Enable Email notification by clicking the switch button d Fill in the information for...

Страница 48: ...p by clicking the switch button i Click the Enable SNMPv1 support check box to activate the SNMPv1 j Enter the Community information the password of the SNMP k Click Add SNMPv1 trap receiver to add a...

Страница 49: ...Enable SNMPv3 support check box to activate the SNMPv3 n Enter the Username the username for authentication of the SNMPv3 server o Click Add SNMPv3 trap receiver to add a trap server p Enter the Rece...

Страница 50: ...gree to automatically notify Infortrend when critical events occur The system will automatically create a support ticket to Infortrend Service Center when any critical errors occur e Check I agree the...

Страница 51: ...one for the device and configure DNS server s on the System settings page Once you are finished click Next 5 The Storage page helps you configure the drives for storage spaces You can set up logical d...

Страница 52: ...ess the volumes By default the system automatically sets all on board data ports for file level access You can change the channel type to block level service manually Once you are finished click Next...

Страница 53: ...d to join the device to an AD server or an LDAP server Click Next to proceed 9 Under Summary all the settings will be displayed for you to check if there is any mistake After you click Start initializ...

Страница 54: ...EonStor CS Installation Guide page 54 97 Installation Guide 10 Wait for the system to apply your configurations Once it is done click Close...

Страница 55: ...dows and macOS clients Contents 4 1 Block level 4 1 1 Create disk Pools During the initial setup wizard process we already created two disk pools however you can still create more than two disk pools...

Страница 56: ...still create more volumes at the GS for different purposes This section outlines the process of creating more volumes for file level 4 2 3 Add Shared Folder s Outline of the process of creating a shar...

Страница 57: ...gs Storage Pools Click Add pool to create a new disk pool 2 Create a pool a Specify your pool name this field is required b Select the write policy in cache memory from the scroll down list There are...

Страница 58: ...gical drive button You will be directed to the page for configuring logical drive parameters 4 Configure logical drive parameters a Select drive members from enclosures and JBOD that are available to...

Страница 59: ...n Guide d Select a stripe size for the logical drive The default may be 128K e Click Apply 5 Once you have completed Logical Drive settings your newly created Logical Drive will appear under the Add l...

Страница 60: ...EonStor CS Installation Guide page 60 97 Installation Guide...

Страница 61: ...reate the current amount of volumes and it has been successfully created you can skip this step If you want to create an additional volume follow the instructions below on how to create a volume 1 Go...

Страница 62: ...EonStor CS Installation Guide page 62 97 Installation Guide...

Страница 63: ...ou will need to map a volume to the host side from management webpage in order to build up storage space to a host operating system Follow the instructions below on how to map a volume to the host 1 G...

Страница 64: ...ion Guide 3 The list of Host LUN mapping configuration will appear Select Create a host LUN mapping set automatically Then Click OK Note If you wish to customize host LUN mapping manually please refer...

Страница 65: ...olumes on the host operating system For Windows OS with the iSCSI protocol please refer to the application notes below https www infortrend com ImageLoader LoadDoc 868 True True Infortrend 20document...

Страница 66: ...ngs Storage Pools Click Add pool to create a new disk pool 2 Create a pool a Specify your pool name this field is required b Select the write policy in cache memory from the scroll down list There are...

Страница 67: ...gical drive button You will be directed to the page for configuring logical drive parameters 4 Configure logical drive parameters a Select drive members from enclosures and JBOD that are available to...

Страница 68: ...n Guide d Select a stripe size for the logical drive The default may be 128K e Click Apply 5 Once you have completed Logical Drive settings your newly created Logical Drive will appear under the Add l...

Страница 69: ...EonStor CS Installation Guide page 69 97 Installation Guide...

Страница 70: ...nt of volumes and it has been successfully created you can skip this step If you want to create and additional volume follow the instructions below on how to create a volume 1 Go to Settings Storage V...

Страница 71: ...EonStor CS Installation Guide page 71 97 Installation Guide...

Страница 72: ...a shared folder for file sharing purpose with different protocol CIFS SMB NFS FTP AFP and Rsync You can share local folders with remote users via the CIFS SMB and NFS protocols 1 Go to Settings Privi...

Страница 73: ...shared folder list Share name Specify a name for the network sharing Users only need to specify share name when CIFS AFP or WebDAV is selected as an access protocol Location Choose the volume that st...

Страница 74: ...ions There are two ways to create users to manage the GS Create Local User After setting up your disk pools folders and shared folders you can start creating users and set up their access permissions...

Страница 75: ...utomatically appear Password expiration Specify the validity period of the user password The user has to change the password when it expires Export the domain user from AD LDAP GS can join a Windows A...

Страница 76: ...to protect the connection with the Windows AD server None or TLS Username Specify the administrative username of the Windows AD server Password Specify the administrative password of the Windows AD se...

Страница 77: ...e LDAP server LDAP Security Select whether to protect the connection with the LDAP server None or TLS Base DN Specify the LDAP base DN distinguished name Examples dc aadomain dc aa local Root DN Speci...

Страница 78: ...gs Privilege Users and user group information in Settings Privilege Groups 6 To update information about domain users click Update the user list Create User Groups After creating the local user and ex...

Страница 79: ...EonStor CS Installation Guide page 79 97 Installation Guide 2 Specify the group name required 3 Select users as group members...

Страница 80: ...EonStor CS Installation Guide page 80 97 Installation Guide...

Страница 81: ...et up the Folder Permission Define the folder access permissions to local domain users and group check below how to set up the folder permission 1 Go to Settings Privilege Shared Folders 2 Check the f...

Страница 82: ...EonStor CS Installation Guide page 82 97 Installation Guide The users groups which have been already created can be listed AD users Domain users can also be listed...

Страница 83: ...EonStor CS Installation Guide page 83 97 Installation Guide...

Страница 84: ...red folders in EonOne 3 Check the protocol setting which you require to use for this shared folder You can check the folder type shown on the folder For example the folder 123 in above picture s proto...

Страница 85: ...EonStor CS Installation Guide page 85 97 Installation Guide 6 Open a file browser Enter the IP address into the address bar and the shared folder s will appear...

Страница 86: ...fficial Website Support Technical Support select the model you have and go to Download Software to download the EonView 2 Find your operating system type and download the corresponding file 3 Launch E...

Страница 87: ...EonStor CS Installation Guide page 87 97 Installation Guide Alternatively enter the specific IP to access the GS...

Страница 88: ...EonStor CS Installation Guide page 88 97 Installation Guide 4 Click Next Enter the account and password to access the GS system 5 Switch to the Shared folders tab...

Страница 89: ...EonStor CS Installation Guide page 89 97 Installation Guide 6 Click Add a shared folder and select the folder you want to mount on the local side...

Страница 90: ...EonStor CS Installation Guide page 90 97 Installation Guide 7 Now you can access this shared folder from your local computer...

Страница 91: ...EonStor CS Installation Guide page 91 97 Installation Guide...

Страница 92: ...fortrend and installing designated updated code including but not limited to firmware microcode basic input out system code utility programs device drivers and diagnostics delivered with Infortrend pr...

Страница 93: ...ty issues that may arise when 1 products software or options not certified and supported by Infortrend are used 2 configurations not certified and supported by Infortrend are used 3 parts intended for...

Страница 94: ...tor and EonServ are registered trademarks or trademarks of Infortrend Technology Inc Other names prefixed with IFT DS GS GSa GSc GSi GSe GSe Pro CS are trademarks of Infortrend Technology Inc All othe...

Страница 95: ...EonStor CS Installation Guide page 95 97 Installation Guide Contact Information...

Страница 96: ...EonStor CS Installation Guide page 96 97 Installation Guide Website For more information of Infortrend s products and services visit https www infortrend com global Home...

Страница 97: ...EonStor CS Installation Guide page 97 97 Installation Guide Customer Support Contact your system vendor or visit the following support site http www infortrend com global Support Support...

Отзывы: