Dual-spectrum Network Bullet Camera User Manual
31
Figure 2.38
Temperature Abnormality Alarm Detection
Region: support full-screen, region 1 -region 6;
Regional Alarm Enable: to start the function of regional alarm detection;
Threshold Type: above threshold -high, below threshold-low/between
threshold-high and threshold-low/outside threshold -high and threshold-low;
Sensor Status: the alarm should be triggered with mode on
(
alarm input and
ground short connected
)
; the video server will always on alarm state with
mode off, the alarm will stop after the alarm is triggered (alarm input and
ground short connected);
Time period detection: support 7 time period detection set.
Trigger Server-end Recording: linkage front-end device recording, the
recording will be stored in the front-end device, such as SD card;
Trigger Server-end Snapshot: linkage front-end device snapshot, the snapshot
will be stored in the front-end devices, such as SD card;
Trigger Alarm Output: to start linkage alarm output.
Alarm level: the temperature of high alarm level should be increased step
by step, the temperature of low alarm level should be reduced step by step.
2.3.5.3 Fire Alarm Detection
Click “Fire Alarm Detection”, the corresponding setting will be unfolded
beneath, see the following figure: