The pan/tilt provides 2 alarm inputs and 2 relay outputs. Each input
can be used to connect an external alarm device such as door
contact, motion sensor or smoke alarm. Relay output can be set to
respond to the alarm input.
By programming the
ALARM FUNCTION
menu, you can define
the normal state (N.O. or N.C.) for each alarm input, and assign it
with an action (a preset) and relay
output
, so that when the normal
state changes to abnormal, the
pan/tilt
will be automatically
positioned at the preset for surveillance and start relay output.
ALARM ENABLE
Function:
enable/disable alarm function. Default setting: disable.
ACTION
Function:
Assign each alarm input with a preset to call upon
alarm.
Options:
NONE -
(default) indicate a no-action command that
disables the automatic preset call.
PRESET 001 ~ PRESET 255 -
select one of the 255
presets as the pan/tilt's alarm action
Operation:
To assign alarm inputs with desired actions (presets)
1. Move the cursor to the ACT entry associated with an alarm input
in use (i.e., that has been properly connected to an alarm device);
2. Deflect the joystick downward (or upward) to select the preset
(1-255);
3. Move the cursor to the ACT entry for the next alarm input in use;
4. Repeat Steps 1 through 3 until all the desired entries have been
defined.
RELAY
Function:
Assign each alarm input with a relay output.
Options:
NONE -
(default) changes of alarm state will not lead to
a relay output.
R 001 –
the first relay output.
R 002 -
the second relay output.
Operation:
To assign alarm input with specific relay output:
1. Move the cursor to the RELAY entry associated with an alarm
input in use;
2. Deflect the joystick downward (or upward) to select a relay
output;
3. Move the cursor to the next RELAY entry associated with an
alarm input in use;
4.
Repeat Steps 2 through 3 until all the entries have been defined.
STATE
Functions:
Define the normal state of each alarm input.
Options:
NO -
(default) indicate the normal state as normally
open (N.O.).
NC -
set the normal state as normally closed (N.C.).
Operation:
To define the normal state for each alarm input in use.
1. Move the cursor to the STATE entry associated with a used alarm
input;
2. Deflect the joystick downward (or upward) to select an appropriate
normal state;
Note:
Since a variety of alarm devices may be utilized, please
refer to the manuals supplied with a particular device to
determine the normal state for the connected alarm input.
3. Move the cursor to the STATE entry associated with the next alarm
input in use;
4. Repeat Steps 2 through 3 until all the entries have been
programmed.
CLEAR TITLE
Function:
Clear the programmed title information of presets,
patterns, areas and AUTOPAN.
Move the cursor to CLEAR TITLE and deflect the
joystick rightward, the following information will be
displayed.
PRESET NO
PATTERN NO
AREA NO
AUTOPAN NO:
RETURN
: ALL CLEAR
: ALL CLEAR
: ALL CLEAR
ALL CLEAR
PRESET NO
Function:
Clear part of or all preset title information.
Options:
001~254 -
Clear title information of the selected preset.
ALL -
Clear the title information of all presets.
PATTERN NO
Function:
Clear part of or all pattern title information.
Options:
001~004-
Clear title information of the selected pattern.
ALL -
Clear the title information of all patterns.
AREA NO
Function:
Clear part of or all area title information.
Options:
001~016 -
Clear title information of the selected area.
ALL -
Clear the title information of all areas.
AUTOPAN
Function:
Clear AUTOPAN title information.
Options:
001~004 -
Clear title information of the selected area.
ALL -
Clear the title information of all areas.
To clear title information:
1. Move the cursor to “ALL” entry;