Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
15
6.
In Log Window, verify that the devices have successfully connected and note the connection handle.
Reset the Write Scan Enable parameters on the reference board
1.
Reestablish the HCI Control Transport profile for the reference board (
com5
).
2.
While in HCI Control: com5@115200, press the
3 key
on the keyboard to select the Host Controller &
Baseband commands.
3.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
4.
In HCI Command: Write_Scan_Enable (com5@115200), in the
Scan_Enable
list, select
No Scans enabled
,
and then click
OK
.
Set the Write Link Policy parameters on the DUT
1.
Reestablish the HCI Control Transport profile for the DUT (
com4
).
2.
While in HCI Control: com4@115200, press the
2 key
on the keyboard to select the Link Policy commands.
3.
In the list of Link Policy commands, double-click
Write_Link_Policy_Settings
.
4.
In HCI Command: Write_Link_Policy_Settings (com4@115200), select the
Enable Sniff Mode
check box, and
then click
OK
.
Set the Write Link Policy parameters on the reference board
1.
Reestablish the HCI Control Transport profile for the reference board (
com5
).
2.
While in HCI Control: com5@115200, press the
2 key
on the keyboard to select the Link Policy commands.
3.
In the list of Link Policy commands, double-click
Write_Link_Policy_Settings
.
4.
In HCI Command: Write_Link_Policy_Settings (com4@115200), select the
Enable Sniff Mode
check box, and
then click
OK
.
Set the Sniff Mode parameters on the DUT
1.
Reestablish the HCI Control Transport profile for the DUT (
com4
).
2.
While in HCI Control: com4@115200, press the
2 key
on the keyboard to select the Link Policy commands.
3.
In the list of Link Policy commands, double-click
Sniff_Mode
.
4.
In HCI Command: Sniff_Mode (com4@115200), make the following settings, and then click
OK
.