Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
10
5.3
Standard 2.56s Inquiry Scan Mode
This section explains how to set the BCM4324/BCM4334 to Standard 2.56s Inquiry Scan mode. Steps include the
following and apply only to the DUT:
■
Set the HCI Control Transport profile.
■
Reset the DUT.
■
Set the Sleepmode Parameters.
■
Set the Scan Type.
■
Generate 4096 slots for 2.56s of activity.
■
Set the Current IAC Lower Address Portion (LAP) parameters.
■
Set the Write Scan Enable parameters.
This section concludes by specifying the approximate ammeter range setting for measuring the current being con-
sumed by the DUT.
Before you begin, set up and turn on the test equipment and launch Cypress BlueTool.
Set the HCI Control Transport profile
1.
Open a log window. On the
View
menu, click
Log Window
.
2.
Set the HCI Control Transport profile.
a.
On the
Transport
menu, click
HCI Control
.
b.
In HCI Control Window Transport:
■
Select
UART
.
■
In the top
UART
list, type the COM port of the PC that the DUT is connected to (
com4
).
■
In the bottom
UART
list, select
115200
.
■
Select the
CTS flow control
check box, and then click
OK
.
Reset the DUT
1.
In HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller & Baseband
commands.
2.
In the list of Host Controller & Baseband commands, double-click
Reset
.
Set the Sleepmode parameters
1.
In HCI Control: com4@115200, press the
0 key
on the keyboard to select the Vendor-specific commands.
2.
In the list of Vendor-specific commands, double-click
Set_Sleepmode_Param
.
3.
In HCI Command: Set_Sleepmode_Param (com4@115200):
a.
Make the following settings:
■
Sleep_Mode
UART
■
Idle_Threshold_Host
0x0
■
Idle_Threshold_HC
0x0
■
BT_WAKE_Active_Mode
Active High
■
Host_WAKE_Active_Mode
Active High
b.
Select the following check boxes, and then click
OK
:
■
Allow_Host_Sleep_During_SCO
■
Combine_Sleep_Mode_And LPM
■
Enable_Tristate_Control_Of_UART_Tx_Line
Set the Scan Type
1.
In HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller & Baseband
commands.
2.
In the list of Host Controller & Baseband commands, double-click
Write_Inquiry_Scan_Type
.
3.
In HCI Command: Write_Inquiry_Scan_Type (com4@115200), in the
Scan_Type
list, select
Mandatory
Standard Scan
, and then click