Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
11
Generate 4096 slots for 2.56s of activity
1.
In the list of Host Controller & Baseband commands, double-click
Write_Inquiry_Scan_Activity
.
2.
In HCI Command: Write_Inquiry_Scan_Activity (com4@115200):
a.
For the
Inquiry_Scan_Interval
, type
4096
in the space provided.
b.
For the
Inquiry_Scan_Window
, type
0x18
in the space provided.
c.
Click
OK
.
Set the Current IAC Lower Address Portion (LAP) parameters
1.
In the list of Host Controller & Baseband commands, double-click
Write_Current_IAC_LAP
.
2.
In HCI Command: Write_Current_IAC_LAP (com4@115200):
a.
For the
Num_Current_IAC
, type
1
in the space provided.
b.
For the
IAC_LAP
, type
10390288
in the space provided.
c.
Click
OK
.
Set the Write Scan Enable parameters
1.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
2.
In HCI Command: Write_Scan_Enable (com4@115200), in the
Scan_Enable
list, select
Inquiry Scan
enabled
, and then click
OK
.
Measure the current consumption
Set the approximate range of the ammeter to 0.2 mA and measure the current being consumed by the DUT.
5.4
Standard Page Scan
This section explains how to set the BCM4324/BCM4334 to Standard Page Scan mode. Steps include the follow-
ing and apply only to the DUT:
■
Set the HCI Control Transport profile.
■
Reset the DUT.
■
Set the Sleepmode parameters.
■
Set the Scan Type.
■
Generate 2048 slots for 1.28s of activity.
■
Set the Write Scan Enable parameters.
This section concludes by specifying the approximate ammeter range setting for measuring the current being con-
sumed by the DUT.
Before you begin, set up and turn on the test equipment and launch Cypress BlueTool.
Set the HCI Control Transport profile
1.
Open a log window. On the
View
menu, click
Log Window
.
2.
Set the HCI Control Transport profile.
a.
On the
Transport
menu, click
HCI Control
.
b.
In HCI Control Window Transport:
■
Select
UART
.
■
In the top
UART
list, type the COM port of the PC that the DUT is connected to (
com4
).
■
In the bottom
UART
list, select
115200
.
■
Select the
CTS flow control
check box, and then click
OK
.
Reset the DUT
1.
While in HCI Control, press the
3 key
on the keyboard to select the Host Controller & Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Reset
.