Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
9
■
Select the
CTS flow control
check box, and then click
OK
.
Reset the DUT
1.
In HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller & Baseband
commands.
2.
In the list of Host Controller & Baseband commands, double-click
Reset
.
Set the Sleepmode parameters
1.
In HCI Control: com4@115200, press the
0 key
on the keyboard to select the to select the Vendor-specific
commands.
2.
In the list of Vendor-specific commands, double-click
Set_Sleepmode_Param
.
3.
In HCI Command: Set_Sleepmode_Param (com4@115200)
a.
Make the following settings:
■
Sleep_Mode
UART
■
Idle_Threshold_Host
0x0
■
Idle_Threshold_HC
0x0
■
BT_WAKE_Active_Mode
Active High
■
Host_WAKE_Active_Mode
Active High
b.
Select the following check boxes, and then click
OK
:
■
Allow_Host_Sleep_During_SCO
■
Combine_Sleep_Mode_And LPM
■
Enable_Tristate_Control_Of_UART_Tx_Line
Set the Scan Type
1.
In HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller & Baseband
commands.
2.
In the list of Host Controller & Baseband commands, double-click
Write_Inquiry_Scan_Type
.
3.
In HCI Command: Write_Inquiry_Scan_Type (com4@115200), in the
Scan_Type
list, select
Mandatory
Standard Scan
, and then click
OK
.
Generate 2048 slots for 1.28s of activity
1.
In the list of Host Controller & Baseband commands, double-click
Write_Inquiry_Scan_Activity
.
2.
In HCI Command: Write_Inquiry_Scan_Activity (com4@115200):
a.
For the
Inquiry_Scan_Interval
, type
2048
in the space provided.
b.
For the
Inquiry_Scan_Window
, type
0x12
in the space provided.
c.
Click
OK
.
Set the Current IAC Lower Address Portion (LAP) parameters
1.
In the list of Host Controller & Baseband commands, double-click
Write_Current_IAC_LAP
.
2.
In HCI Command: Write_Current_IAC_LAP (com4@115200):
a.
For the
Num_Current_IAC
, type
1
in the space provided.
b.
For the
IAC_LAP
, type
10390288
in the space provided.
c.
Click
OK
.
Set the Write Scan Enable parameters
1.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
2.
In HCI Command: Write_Scan_Enable (com4@115200), in the
Scan_Enable
list, select
Inquiry Scan
enabled
, and then click
OK
.
Measure the current consumption
Set the approximate range of the ammeter to 0.2 mA and measure the current being consumed by the DUT.