Industrial Shields PLC 10 Скачать руководство пользователя страница 7

Ref.

 

013001000100   

 

 

 

 

 

     Rev.1: 18-01-2021       

 

 

Intended use or of Industrial Shields products                                                 

 

Consider the following: 

Industrial Shields products should only be used for the cases of application foreseen in 
the  catalogue  and the  associated technical  documentation.  If third-party products  and 
components  are  used,  they  must  have  been  recommended  or  approved  by  Industrial 
Shields.  

The  correct  and  safe  operation  of  the  products  requires  that  your  transport,  storage, 
installation, assembly, operation and maintenance have been carried out in a correct It 
must respect the permissible ambient conditions. You should also follow the indications 
and warnings that appear in the associated documentation. 

The  product  /  system  dealt  with  in  this  documentation  should  only  be  handled  or 
manipulated  by  qualified  personnel  for  the  task  entrusted  and  observing  what  is 
indicated  in  the  documentation  corresponding  to  it,  particularly  the  safety  instructions 
and  warnings  included  in  it.  Due  to  their  training  and  experience,  qualified  personnel 
are in a position to recognize risks resulting from the handling or manipulation of such 
products / systems and to avoid possible hazards. 

Disclaimers             

Weights and Dimensions 

Dimensions  and  weights  are  nominal  and  they  are  not  used  for  manufacturing 
purposes, even when tolerances are shown. 

Performance Data 

The  performance  data  given  in  this  manual  is  provided  as  a  guide  for  the  user  in 
determining suitability and does not constitute a warranty. It may represent the result of 
INDUSTRIAL  SHIELDS’s  test  conditions,  and  the  users  most  correlate  it  to  actual 
application requirements. Actual performance is subject to the INDUSTRIAL SHIELDS 
Warranty and Limitations of Liability. 

Change in Specifications 

Product  specifications  and  accessories  may  be  changed  at  any  time  based  on 
improvements and other reasons. 

It  is  our  practice  to  change  model  numbers  when  features  are  changed,  or  published 
ratings  or  when  significant  construction  changes  are  made.  However,  some 
specifications  of  the  products  may  be  changed  without  any  notice.  When  in  doubt, 
special  numbers  may  be  assigned  to  fix  or  stablish  key  specifications  for  your 
application  on  your  request.  Please  consult  with  your  INDUSTRIAL  SHIELDS 
representative at any time to confirm actual specifications of purchased products. 

 

Содержание PLC 10

Страница 1: ...PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO...

Страница 2: ...Ref 013001000100 Rev 1 18 01 2021 1...

Страница 3: ...100 Rev 1 18 01 2021 2 PLC 10 I Os Digital Module CPU ARDUINO NANO User Guide Revised September 2020 This user guide is for version PLC 10 I Os Digital Module CPU ARDUINO NANO with Reference name Ref...

Страница 4: ...ing the directive may damage the controller Improper use of this product may severely damage the controller Refer to the controller s User Guide regarding wiring considerations Before using this produ...

Страница 5: ...e effectu e par personnel qualifi familiaris avec la fabrication le fonctionnement et les dangers li s au contr leur La maintenance doit tre effectu e avec l quipement hors service et d connect e de t...

Страница 6: ...any codes regulations or standards that apply to the combination of products in the customer s application or use of the product The following are some examples of applications for which particular a...

Страница 7: ...ze risks resulting from the handling or manipulation of such products systems and to avoid possible hazards Disclaimers Weights and Dimensions Dimensions and weights are nominal and they are not used...

Страница 8: ...nts during commissioning operation maintenance and repairs caused by for example Hardware defects and or software errors in the sensors controllers actuators and connection technology Response times o...

Страница 9: ...ED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE INDUSTRIAL SHIELDS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED Limitations of Liability INDUSTRIAL SHIELDS SHALL NO...

Страница 10: ...are Interface 14 5 How to connect PLC ARDUINO NANO to PC 17 6 How to connect PLC to power supply 18 7 10 I Os Digital Module pinout 19 Left Zone Connections 19 Right Zone Connections 20 Top Zone Conne...

Страница 11: ...Power 30 W I Max 1 5A Size 100x45x115 Clock Speed 16 MHz Flash Memory 32KB of which 2KB are used by bootloader SRAM 2 KB EEPROM 1 KB Communications USB RS485 ETH MAX487CSA W5500 USB Consideration Only...

Страница 12: ...l the external AC terminals and the protective earth terminal Shock resistance 80m s2 in the X Y and Z direction 2 times each Ambient temperature operating 0 to 60 C Ambient humidity operating 10 to 9...

Страница 13: ...g current only to identify relevant terminals IEC 60417 Graphical symbols for use on equipment 5130 Pulse General To identify the control by which a pulse is started IEC 60417 Graphical symbols for us...

Страница 14: ...cations described in this manual Before using 10 I Os Digital Module CPU ARDUINO NANO under different conditions from what has been specified in this manual or integrating 10 I Os Digital Module CPU A...

Страница 15: ...h easier Basically it is no needed to define the pins and if that pins are inputs or outputs Everything is set up automatically if using the boards In order to install Industrial Shields boards these...

Страница 16: ...Ref 013001000100 Rev 1 18 01 2021 15 4 Go to Tools Board Boards Manager 5 Search for industrialshields megaavr on the browser 6 Click install industrialshields megaavr selecting the latest version...

Страница 17: ...d 10 IOs PLC Family an extra option will appear on Tools There it can be selected the exact model for every family In this case 10 IOS PLC Also there are some examples of programming in File Examples...

Страница 18: ...t PLC ARDUINO NANO to PC Connect USB port from PLC to PC NOTE 10 I Os Family uses micro USB cable Open Arduino IDE interface Select Industrial Shields megaAVR boards 10 IOS PLC Family Select the corre...

Страница 19: ...ies regardless of where use of the device is intended The equipment must be powered from an external power source in accordance with IEC 61010 1 whose output is MBTS and is limited in power according...

Страница 20: ...Pin Function Q 0 9 Q 0 8 Q 0 7 Q 0 6 Q 0 5 Q 0 4 Q 0 3 Q 0 2 Q 0 1 Q 0 0 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Output Digital Output Digital Output Digital Output Digital Output Digital Output Digital...

Страница 21: ...0 9 I 0 8 I 0 7 I 0 6 I 0 5 GNDCOM2 I 0 4 I 0 3 I 0 2 I 0 1 I 0 0 GNDCOM1 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Input Digital Input Digital Input Digital Input Digital Input Ground Digital Input Digit...

Страница 22: ...EDs positioned at the top of the PLC which go from led 0 to 9 refer to both inputs and outputs For example if you are using input I0 9 LED 9 on the top cover of the PLC will indicate the signal status...

Страница 23: ...ts There is a Jumper Zone 1 with three pins on each side of the board In the case of using the pins as Inputs the jumper must be connected on the pins 1 and 2 Otherwise if the pin is wished to work as...

Страница 24: ...age the device and could burn it This jumper zone makes the choosing between a 5V and 24 V The 24V option will be used in the case of using the pins as OUTPUT as it will provides the same voltage as t...

Страница 25: ...Ref 013001000100 Rev 1 18 01 2021 24...

Страница 26: ...Ref 013001000100 Rev 1 18 01 2021 25 I Os Configuration examples Input mode Low voltage This is an exemple to configure 0 9 as an input with the 3 3 24V current range...

Страница 27: ...Ref 013001000100 Rev 1 18 01 2021 26 High voltage This is an exemple to configure 0 9 as an input with the 230V current range...

Страница 28: ...Ref 013001000100 Rev 1 18 01 2021 27 Output mode Low voltage This is an exemple to configure 0 9 as an output with the 3 3 24V current range...

Страница 29: ...C of the connection between Arduino NANO pins the RS 485 chip and its outputs Using the boards of Industrial Shields there is a library that simplifies the RS 485 implementation Ethernet 10 I Os Ether...

Страница 30: ...Ref 013001000100 Rev 1 18 01 2021 29 10 Typical Connections 3 3 24v...

Страница 31: ...nnection details Article reference MC 0 5 6 G 2 5 THT Height 8 1mm Pitch 2 5mm Dimension 22 5mm Pin dimensions 0 8x0 8mm Pin spacing 2 50mm Article reference M1 5 6 G 3 81 Height h 10 65mm Pitch 3 81m...

Страница 32: ...Ref 013001000100 Rev 1 18 01 2021 31 12 10 I Os Family Dimensions 45mm width DIN rail mounting...

Страница 33: ...ocation has high ambient temperature or heat generating equipment nearby install forced convection devices on top or sides of the cabinet to avoid over temperature During drilling or wiring prevent th...

Страница 34: ...be checked to assure its integrity Accumulations of dust and dirt on all parts including on semiconductor heat sinks should be removed according to the manufacturer s instructions if provided otherwi...

Страница 35: ...ing can damage the screws and or the module with the risk of falling short circuits and malfunctions Before handling a module dispose of the electrostatic charge accumulated by the human body by touch...

Страница 36: ...Ref 013001000100 Rev 1 18 01 2021 35 14 Revision Table Revision Number Date Changes 0 14 09 2020 First implementation 1 18 01 2021 Added Software Section 4...

Страница 37: ...01 2021 36 About Industrial Shields Direction F brica del Pont 1 11 Zip Postal Code 08272 City Sant Fruit s de Bages Barcelona Country Spain Telephone 34 938 760 191 34 635 693 611 Mail industrialshie...