Industrial Shields PLC 10 Скачать руководство пользователя страница 13

Ref.

 

013001000100   

 

 

 

 

 

     Rev.1: 18-01-2021       

 

12 

 

Program capacity (SRAM) 

6KB 

EEPROM 

156B

 

Clock Speed 

16 MHz

 

 

Symbology 

Table that includes all the symbology that is used in the serigraph of the PLC 10 I/Os Digital 
Module CPU Aduino Nano: 

Symbol 

 

Standard No. / 

Standard Title 

 

Standard 

Reference No. / 

Symbol Title 

Symbol Meaning 

 

IEC 60417 / 

Graphical symbols 

for use on 

equipment 

5031 / Direct 

Current 

Indicates that the equipment is 

suitable for direct current only; 

to identify relevant terminals 

 

IEC 60417 / 

Graphical symbols 

for use on 

equipment 

 

5032 / Alternating 

Current 

Indicates that the equipment is 

suitable for alternating current 

only; to identify relevant 

terminals 

 

 

IEC 60417 / 

Graphical symbols 

for use on 

equipment 

 

5130 / Pulse 

General 

To identify the control by 

which a pulse is started. 

 

 

IEC 60417 / 

Graphical symbols 

for use on 

equipment 

 

5017 / Earth, 

Ground 

To identify an earth (ground) 

terminal in cases where 

neither the symbol 5018 nor 

5019 is explicily required. 

 

 

IEC 60417 / 

Graphical symbols 

for use on 

equipment 

 

5115 / SIgnal lamp 

To identify the switch by 

means of which the signal 

lamp(s) is (are) switched on or 

off. 

 

Medical Devices 

Directive 

93/42/EEC 

CE Marking 

CE marking indicates that a 

product complies with 

applicable European Union 

regulations 

 
 

ISO 7000/ 

Graphical symbols 

for use on 

equipment 

 

0434B / 

Warning symbol 

Indicates a potentially 

hazardous situation which, if 

not avoided, could result in 

death or serious injury 

Содержание PLC 10

Страница 1: ...PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO PLC 10 I Os DIGITAL MODULE CPU ARDUINO NANO...

Страница 2: ...Ref 013001000100 Rev 1 18 01 2021 1...

Страница 3: ...100 Rev 1 18 01 2021 2 PLC 10 I Os Digital Module CPU ARDUINO NANO User Guide Revised September 2020 This user guide is for version PLC 10 I Os Digital Module CPU ARDUINO NANO with Reference name Ref...

Страница 4: ...ing the directive may damage the controller Improper use of this product may severely damage the controller Refer to the controller s User Guide regarding wiring considerations Before using this produ...

Страница 5: ...e effectu e par personnel qualifi familiaris avec la fabrication le fonctionnement et les dangers li s au contr leur La maintenance doit tre effectu e avec l quipement hors service et d connect e de t...

Страница 6: ...any codes regulations or standards that apply to the combination of products in the customer s application or use of the product The following are some examples of applications for which particular a...

Страница 7: ...ze risks resulting from the handling or manipulation of such products systems and to avoid possible hazards Disclaimers Weights and Dimensions Dimensions and weights are nominal and they are not used...

Страница 8: ...nts during commissioning operation maintenance and repairs caused by for example Hardware defects and or software errors in the sensors controllers actuators and connection technology Response times o...

Страница 9: ...ED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE INDUSTRIAL SHIELDS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED Limitations of Liability INDUSTRIAL SHIELDS SHALL NO...

Страница 10: ...are Interface 14 5 How to connect PLC ARDUINO NANO to PC 17 6 How to connect PLC to power supply 18 7 10 I Os Digital Module pinout 19 Left Zone Connections 19 Right Zone Connections 20 Top Zone Conne...

Страница 11: ...Power 30 W I Max 1 5A Size 100x45x115 Clock Speed 16 MHz Flash Memory 32KB of which 2KB are used by bootloader SRAM 2 KB EEPROM 1 KB Communications USB RS485 ETH MAX487CSA W5500 USB Consideration Only...

Страница 12: ...l the external AC terminals and the protective earth terminal Shock resistance 80m s2 in the X Y and Z direction 2 times each Ambient temperature operating 0 to 60 C Ambient humidity operating 10 to 9...

Страница 13: ...g current only to identify relevant terminals IEC 60417 Graphical symbols for use on equipment 5130 Pulse General To identify the control by which a pulse is started IEC 60417 Graphical symbols for us...

Страница 14: ...cations described in this manual Before using 10 I Os Digital Module CPU ARDUINO NANO under different conditions from what has been specified in this manual or integrating 10 I Os Digital Module CPU A...

Страница 15: ...h easier Basically it is no needed to define the pins and if that pins are inputs or outputs Everything is set up automatically if using the boards In order to install Industrial Shields boards these...

Страница 16: ...Ref 013001000100 Rev 1 18 01 2021 15 4 Go to Tools Board Boards Manager 5 Search for industrialshields megaavr on the browser 6 Click install industrialshields megaavr selecting the latest version...

Страница 17: ...d 10 IOs PLC Family an extra option will appear on Tools There it can be selected the exact model for every family In this case 10 IOS PLC Also there are some examples of programming in File Examples...

Страница 18: ...t PLC ARDUINO NANO to PC Connect USB port from PLC to PC NOTE 10 I Os Family uses micro USB cable Open Arduino IDE interface Select Industrial Shields megaAVR boards 10 IOS PLC Family Select the corre...

Страница 19: ...ies regardless of where use of the device is intended The equipment must be powered from an external power source in accordance with IEC 61010 1 whose output is MBTS and is limited in power according...

Страница 20: ...Pin Function Q 0 9 Q 0 8 Q 0 7 Q 0 6 Q 0 5 Q 0 4 Q 0 3 Q 0 2 Q 0 1 Q 0 0 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Output Digital Output Digital Output Digital Output Digital Output Digital Output Digital...

Страница 21: ...0 9 I 0 8 I 0 7 I 0 6 I 0 5 GNDCOM2 I 0 4 I 0 3 I 0 2 I 0 1 I 0 0 GNDCOM1 D9 D6 D5 D3 D2 A6 A3 A2 A1 A0 Digital Input Digital Input Digital Input Digital Input Digital Input Ground Digital Input Digit...

Страница 22: ...EDs positioned at the top of the PLC which go from led 0 to 9 refer to both inputs and outputs For example if you are using input I0 9 LED 9 on the top cover of the PLC will indicate the signal status...

Страница 23: ...ts There is a Jumper Zone 1 with three pins on each side of the board In the case of using the pins as Inputs the jumper must be connected on the pins 1 and 2 Otherwise if the pin is wished to work as...

Страница 24: ...age the device and could burn it This jumper zone makes the choosing between a 5V and 24 V The 24V option will be used in the case of using the pins as OUTPUT as it will provides the same voltage as t...

Страница 25: ...Ref 013001000100 Rev 1 18 01 2021 24...

Страница 26: ...Ref 013001000100 Rev 1 18 01 2021 25 I Os Configuration examples Input mode Low voltage This is an exemple to configure 0 9 as an input with the 3 3 24V current range...

Страница 27: ...Ref 013001000100 Rev 1 18 01 2021 26 High voltage This is an exemple to configure 0 9 as an input with the 230V current range...

Страница 28: ...Ref 013001000100 Rev 1 18 01 2021 27 Output mode Low voltage This is an exemple to configure 0 9 as an output with the 3 3 24V current range...

Страница 29: ...C of the connection between Arduino NANO pins the RS 485 chip and its outputs Using the boards of Industrial Shields there is a library that simplifies the RS 485 implementation Ethernet 10 I Os Ether...

Страница 30: ...Ref 013001000100 Rev 1 18 01 2021 29 10 Typical Connections 3 3 24v...

Страница 31: ...nnection details Article reference MC 0 5 6 G 2 5 THT Height 8 1mm Pitch 2 5mm Dimension 22 5mm Pin dimensions 0 8x0 8mm Pin spacing 2 50mm Article reference M1 5 6 G 3 81 Height h 10 65mm Pitch 3 81m...

Страница 32: ...Ref 013001000100 Rev 1 18 01 2021 31 12 10 I Os Family Dimensions 45mm width DIN rail mounting...

Страница 33: ...ocation has high ambient temperature or heat generating equipment nearby install forced convection devices on top or sides of the cabinet to avoid over temperature During drilling or wiring prevent th...

Страница 34: ...be checked to assure its integrity Accumulations of dust and dirt on all parts including on semiconductor heat sinks should be removed according to the manufacturer s instructions if provided otherwi...

Страница 35: ...ing can damage the screws and or the module with the risk of falling short circuits and malfunctions Before handling a module dispose of the electrostatic charge accumulated by the human body by touch...

Страница 36: ...Ref 013001000100 Rev 1 18 01 2021 35 14 Revision Table Revision Number Date Changes 0 14 09 2020 First implementation 1 18 01 2021 Added Software Section 4...

Страница 37: ...01 2021 36 About Industrial Shields Direction F brica del Pont 1 11 Zip Postal Code 08272 City Sant Fruit s de Bages Barcelona Country Spain Telephone 34 938 760 191 34 635 693 611 Mail industrialshie...

Отзывы: