Ref. IS.MDUINO.58+
Rev. 0: 30-08-2019
31
8.2
B, C & D Zone Swithces
For the Analog Shield if a switch is set to ON, it can only act as Digital Output. If it is set to OFF
it can only act as an Analog Output.
If it is desired to use a Digital Output the pin must be set to ON and the pin that will provide
this digital output is represented with QX.X, being X any number of the tables above.
If it is desired to use an Analog Output the pin must be set to OFF and the pin that will provide
this analog output is represented with AX.X, being X any number of the tables above.
B ZONE
SWITCH
ON
OFF
NC
-
-
Q0.7
Q0.7 A0.7
Q0.6
Q0.6 A0.6
Q0.5
Q0.5 A0.5
C ZONE
SWITCH
ON
OFF
NC
-
-
Q1.7
Q1.7 A1.7
Q1.6
Q1.6 A1.6
Q1.5
Q1.5 A1.5
D ZONE
SWITCH
ON
OFF
NC
-
-
Q2.7
-
-
Q2.6
Q2.6 A2.6
Q2.5
Q2.5 A2.5