When one or two transmitter or receiver cards are in use,
only one power supply is used; the used Power Connector
LED lights.
•
When three or more transmitter or receiver cards are in use,
both power supplies are used, and both Power Connector
LEDs are lit.
Generate a PSU Failure Event in Control Center
If you are using IndigoVision’s Control Center application, you can
specify that an alarm is generated if one of the power supplies to
the 10 Channel Rack fails.
There are three steps you must take:
1. Set the back panel jumpers to the correct position.
2. Configure the binary input using the Web Configuration pages.
3. Specify the alarm source in Control Center.
Set the Back Panel Jumpers
Two jumpers are positioned on the back panel of the Rack next to
the serial connector:
Jumpers
Figure 8
Setting back panel jumpers
Figure 9
Back panel jumpers - detail