7.
When cleaning the drive area, make sure that the dirt does not
penetrate directly into the path measuring systems and the
ballscrews. The cleaning process must not aggravate the
contamination of the components.
Clean drive area. Spray cooling lubricant onto the area around the supports of
the guide bars and then sweep off the rough dirt down into the drag of the
machine with a hand brush. Afterwards rub with rags.
8.
When cleaning the spindle carriers, make sure that the dirt does
not penetrate directly into the spindle encoders. The cleaning
process must not aggravate the contamination of the
components. Follow the manufacturer’s documentation.
Cleaning of the spindle carriers of the main and counter spindles. Remove
machine covers in the area of the spindles. Then remove and clean the spindle
covers.
9. Clean the machine drag. Remove accumulations of chips, especially in the
area of the counter spindle. For this purpose, move the counter spindle towards
the main spindle and flush the area with cooling lubricant in the direction of the
chip conveyor. Sweep the dirt arising from the cleaning of the drive area also in
the direction of the chip conveyor and then flush with cooling lubricant.
Afterwards rub with rags.
10. Clean and reinstall machine covers.
11. Clean the drip pan under the workpiece handling unit.
Maintenance Summary - 4.000 Operating hours
68
Maintenance Instructions
G200.2
DIE078EN - 05.06.2019
Содержание G200.2
Страница 6: ...Table of contents IV Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 10: ...Preface 4 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 40: ...Maintenance Summary Care activities 34 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 70: ...Maintenance Summary 2 000 Operating hours 64 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 94: ...Maintenance Summary 4 000 Operating hours 88 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 99: ...Service Interval 5 Years Service Interval 5 Years 93 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 103: ...Service Interval 8 Years Service Interval 8 Years 97 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...