Example: Checking the obstacle detection
Check obstacle detection of the automatic work area door. To check the
obstacle detection, an object, e.g., a broomstick (see example), is held into the
travel path of the work area door while it is closing. When the work area door
contacts the broom stick in the closing area, the obstacle detection is triggered
and the door should stop its forward movement.
Maintenance Summary - 2.000 Operating hours
39
Maintenance Instructions
G220