17
Further Components:
Other components are different in appearance but have the same functions as the ones on the previous model EVO3. This does
not necessarily mean that they are interchangeable, as their techinical features are quite different eg. as in the Pressostat.
(1)
The Brushless motor cannot be controlled. The motor is controlled by an electronic-main-board inside.
(2)
Thermo-protector: 95°C +/-5°C - Thermofuse 206C +/- 10°C
(3)
Thermo-protector: 95°C +/-5°C - Thermofuse 206C +/- 10°C
(4)
Thermo-protector: 95°C +/-5°C - Thermofuse 206C +/- 10°C
Electric
Component
Volts
Frequency
Watts
Ohm
Amp
Electric-valve
charge
220/240
50/60 Hz
+/- 8 W
3720
Ω
0,03
Electric-valve
Water-stop
220/240
50/60 Hz
+/- 8 W
4130
Ω
+/-10%
(20°C)
0,03
Electric-valve
Regenerator
220/240
50/60 Hz
+/- 7W
4109
Ω
0,02
Solenoid-
Dispenser
220/240
50Hz
---
1619
Ω
0,03
Discharging
Pump
220/240
50Hz
26 W
216
Ω
+/-7%
0,19
Synchro-heating
element (all
mkts)(3)
220/240
50Hz
1800 W+/-5%
29.2
Ω
+/-5%
8
Synchro-heating
element (UK)(2)
220/240
50Hz
1800 W+/-5%
31,8
Ω
+/- 5%
8
Heating-element
BLDC
220/240
50 Hz
1800 W+/-5%
31.5
Ω
+/- 5%
8
Brushless
Motor(1)
----
---
----
----
----