MMP-1: INSTALLATION & OPERATION MANUAL
PAGE 8
The MMP-1 can be connected in different ways to various audio devices.
Please note the MMP-1 is designed to work using only one output connection at a time. Please see page 9.
*Note: Connecting multiple inputs and outputs and the same time could cause damage to the MMP-1, or
other connected equipment.
Cable Type
As power and audio travel along the same cable from the MMP1 - through the PoE power supply to other
devices, the category network cable connected between the MMP-1 and all devices must be of a high
quality.
A shielded category network cable with shielded RJ45 terminations must be used.
*Note: The minimum network category cable type requirement is CAT6A. The Length of cable must not
exceed 100 metres between the MMP-1 and PoE power supply. Cables must be terminated with shielded
RJ45 connectors in T-568B standard.
CONNECTING YOUR MMP-1
RJ45 PIN
CONDUCTOR FUNCTION
CAT 6A CONDUCTOR COLOUR
1
Balanced audio +
White + Orange
2
Balanced audio -
Orange
3
White + Green
4
V 24V
Blue
5
V 24V
White + Blue
6
Green
7
Vsupply - 24V
White + Brown
8
Vsupply - 24V
Brown
Connector Screen
Audio Ground
Screen / Braid