User Manual
27
Excess ice on the
evaporator.
Moisture infiltration in the
product.
Check the conditions of the gasket on
all four sides of the door. The gasket
must close perfectly on the unit. If the
formation of ice is thicker on one side,
most likely there is moisture infiltration in
the refrigerator is coming from that side.
Use a moderate heat source to model the
gasket into position. If the gasket cannot
be modelled, replace the entire door.
The refrigerator cools too
much.
The thermostat sensor is
too covered or incorrectly
positioned
The end of the sensor must be in contact
with the evaporator. Set the sensor in
the correct position. If the refrigerator
continues to cool too much, replace the
thermostat.
The compressor is noisier
than normal.
The compressor is not
properly secured on its
support or it is touching the
wall.
Check that compressor screws are properly
tightened and that nothing is in contact
with it. The compressor vibrates and, if
something is in contact with it, vibrations
increase.
The fan/s is/are noisier than
normal.
The fan structure is bent or
the fan is broken.
Remove the clamps/screws used to secure
the fan. Replace if the fan continues to
make noise. Make sure that all of the fan
is intact. Replace if one or more fins is
missing.
The internal light does not
switch on.
Polarity reversed or broken
bulb.
Check bulb polarity. Replace light bulb if
polarity is correct.
Door/Drawer not closing
properly.
Incorrect position of hinges or
deformed gasket.
Re-position hinges so that the door closes
correctly. Use a moderate heat source
to remodel the gasket. Replace door if
problem persists. In the case of drawer
refrigerators, use the adjustable guides to
align the door.
For more complicated defects requiring specialised assistance, please contact Indel
Webasto Marine S.r.l. Italia or your nearest Isotherm retailer.
Содержание BI29 Dual
Страница 2: ......
Страница 3: ......
Страница 4: ...4 Isotherm Built In Serie Fig 1...
Страница 5: ...5 Isotherm Built In Serie Fig 2...
Страница 6: ...6 Isotherm Built In Serie Fig 3...
Страница 7: ...7 Isotherm Built In Serie Fig 4...
Страница 8: ...8 Isotherm Built In Serie Fig 5...
Страница 9: ......
Страница 33: ......
Страница 40: ...Manuale d uso 39 ATTENZIONE Non utilizzare spine o interruttori se avete mani o piedi bagnati...
Страница 58: ......
Страница 82: ......
Страница 106: ......
Страница 130: ......
Страница 154: ......
Страница 178: ......
Страница 202: ......
Страница 204: ...202 1...
Страница 205: ...203 INDEL INDEL Webasto Marine S r l Webasto Marine S r l 1 1 2002 96 CE RAEE...
Страница 206: ...204 R134a R134a R134a R134a R134a R134a 1 2 1 2 Indel Webasto Marine S r l Indel Webasto Marine S r l...
Страница 207: ...205...
Страница 208: ...206 115 230 115 230 8 8 8 8...
Страница 209: ...207 2 SN 10 C 32 C N 16 C 32 C ST 16 C 38 C T 16 C 43 C 2 1 A 1 7 B 5 6 C B A...
Страница 211: ...209 3 3 Isotherm Built In 3 1 3 4 3 2 1 2...
Страница 212: ...210 3 3 0 C 4 12 9 6 10 4 10 9 11 7 24 21 3 22 8 22 7 24 2...
Страница 213: ...211 5 5 Indel Webasto Marine S r l Indel Webasto Marine S r l...
Страница 214: ...212 EN 603 335 1 5 EN 603 335 1 5 Heavy Current Heavy Current Regulations Regulations 115 115 230 230...
Страница 216: ...214 5 2 1 2 5 3 12 24 I 0 03A 12 24 BI29Dual BI36 BI40 BI41Dual BI53F BI75 BI92Dual 15A 7 5A...
Страница 217: ...215 5 4 2 AWG 12 24 2 5 13 2 5 8 5 16 4 11 4 13 8 26 6 9 6 19 12 39 10 7 10 33 20 66 5 5 4 5 Indel Webasto Marine Srl...
Страница 219: ...217 7 T C 4 4...
Страница 220: ...218 C P C T...
Страница 221: ...219 Indel Webasto Marine Isotherm...
Страница 222: ...220 8 6 5 4 1 850 3 5 2 1A 1...
Страница 224: ...222 10 Indel Webasto Marine 1999 44 2 IWM Indel Webasto Marine USA b S N...
Страница 226: ...224...
Страница 227: ...225 Isotherm Built In Serie AC DC Built In 12 24 Volt 115 230 Volt...
Страница 228: ......
Страница 229: ......