User Manual
26
The fuse blows.
The wrong fuse is being used.
Defective electronic control
unit.
Check the fuse: see table in section 5.4.
Replace the electronic control unit.
The compressor is operating
intermittently.
Battery low or electrical cables
in poor conditions.
Check wiring conditions, examining for
loose connections, rust or verdigris. If
wiring needs to be replaced, see the
manual for correct sizing. If wiring is in
good conditions, check battery function
and replace if in poor condition.
The compressor never stops
(correct fridge performance)
Incorrect thermostat
connection on the electronic
control unit. Thermostat
broken. Condensation is not
working properly, evaporator
cools but not enough to cause
the thermostat to stop the
compressor.
Rotate the thermostat to off position. If
the refrigerator continues to function,
then there is continuity on the control
unit. Correct the problem on thermostat
connections (make sure the bridge
is present on C and P and not on C
and T on the electronic control unit).
Rotate the thermostat to off position.
If the compressor switches off but it is
impossible to regulate temperature,
replace the thermostat or recharge the
cooling system.
The compressor never stops
(poor fridge performance)
Environment very hot +
insufficient ventilation or little
gas in the refrigerant circuit.
Check ventilation. The compressor must
be installed in a well-ventilated location.
If possible, remove the refrigerator from
the installation hole. If the refrigerator
operates better, improve ventilation,
consulting the manual for correct
installation. If ventilation is instead
optimal, check for the presence of gas
in the system, contacting a specialised
technician.
The freezer compartment
is cold but the refrigerator
is not
Insufficient ventilation,
little gas in the refrigerant
circuit, electrical power not
continuous.
Check ventilation. The compressor must
be installed in a well-ventilated location.
If possible, remove the refrigerator from
the installation hole. If the refrigerator
operates better, improve ventilation,
consulting the manual for correct
installation. Check electrical connection
and battery conditions. If ventilation is
instead optimal, check for the presence of
gas in the system, contacting a specialised
technician.
Содержание BI29 Dual
Страница 2: ......
Страница 3: ......
Страница 4: ...4 Isotherm Built In Serie Fig 1...
Страница 5: ...5 Isotherm Built In Serie Fig 2...
Страница 6: ...6 Isotherm Built In Serie Fig 3...
Страница 7: ...7 Isotherm Built In Serie Fig 4...
Страница 8: ...8 Isotherm Built In Serie Fig 5...
Страница 9: ......
Страница 33: ......
Страница 40: ...Manuale d uso 39 ATTENZIONE Non utilizzare spine o interruttori se avete mani o piedi bagnati...
Страница 58: ......
Страница 82: ......
Страница 106: ......
Страница 130: ......
Страница 154: ......
Страница 178: ......
Страница 202: ......
Страница 204: ...202 1...
Страница 205: ...203 INDEL INDEL Webasto Marine S r l Webasto Marine S r l 1 1 2002 96 CE RAEE...
Страница 206: ...204 R134a R134a R134a R134a R134a R134a 1 2 1 2 Indel Webasto Marine S r l Indel Webasto Marine S r l...
Страница 207: ...205...
Страница 208: ...206 115 230 115 230 8 8 8 8...
Страница 209: ...207 2 SN 10 C 32 C N 16 C 32 C ST 16 C 38 C T 16 C 43 C 2 1 A 1 7 B 5 6 C B A...
Страница 211: ...209 3 3 Isotherm Built In 3 1 3 4 3 2 1 2...
Страница 212: ...210 3 3 0 C 4 12 9 6 10 4 10 9 11 7 24 21 3 22 8 22 7 24 2...
Страница 213: ...211 5 5 Indel Webasto Marine S r l Indel Webasto Marine S r l...
Страница 214: ...212 EN 603 335 1 5 EN 603 335 1 5 Heavy Current Heavy Current Regulations Regulations 115 115 230 230...
Страница 216: ...214 5 2 1 2 5 3 12 24 I 0 03A 12 24 BI29Dual BI36 BI40 BI41Dual BI53F BI75 BI92Dual 15A 7 5A...
Страница 217: ...215 5 4 2 AWG 12 24 2 5 13 2 5 8 5 16 4 11 4 13 8 26 6 9 6 19 12 39 10 7 10 33 20 66 5 5 4 5 Indel Webasto Marine Srl...
Страница 219: ...217 7 T C 4 4...
Страница 220: ...218 C P C T...
Страница 221: ...219 Indel Webasto Marine Isotherm...
Страница 222: ...220 8 6 5 4 1 850 3 5 2 1A 1...
Страница 224: ...222 10 Indel Webasto Marine 1999 44 2 IWM Indel Webasto Marine USA b S N...
Страница 226: ...224...
Страница 227: ...225 Isotherm Built In Serie AC DC Built In 12 24 Volt 115 230 Volt...
Страница 228: ......
Страница 229: ......