SW BACK&TOP
SW_BACK&TOP_28-02-2019
42
OPERATION/CONTROL PANEL
“Sleeping Well”
CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY
CONDITIONING (AC)
T
0
:
TEMPERATURE SET BY USER
T
amb
:
AMBIENT TEMPERATURE DETECTED BY PROBE
V
1
:
COMPRESSOR ROTATION SPEED
(2500 Rpm)
V
2
:
COMPRESSOR ROTATION SPEED
(4000 Rpm)
ON/OFF
When the system is switched off, pressing the
ON/OFF
button (see fig.1) for more than 2 seconds switches on the
AC
system in
STANDARD
mode (V
1
) for a maximum of 6 consecutive hours and the half snowflake symbol lights up.
If the system is switched on, pressing this button for more than 2 seconds switches off the
AC
system.
About 30” after switching on, the ventilation starts up automatically.
The display always shows the temperature set by the user (T
0
).
The temperature which can be set by the user is between 17°C and 28°C.
TURBO
When the system is switched on, (by default in
STANDARD
mode - V
1
) pressing
TURBO
(see fig.1), the maximum yield of the system is obtained
by running the compressor at rotation speed V
2
for 4 consecutive hours and the full snowflake symbol lights up.
Once this function has been activated, press the
TURBO
button again to return to speed V
1
.
TIMER
In
STANDARD
mode, the operating hours envisaged by the timer are 6.
In
TURBO
mode, the operating hours envisaged by the timer are 4.
If the system is switched on, every quick press of
TIMER
button (see fig.1) reduces the system operating time by 1 hour.
In
TURBO
mode, this button can be pressed to reduce the compressor operating time at speed V
2
from 4 to 1 in steps of 1 hour.
Set the
TIMER
according to the power available.
TIMER ADJUSTMENT
When the system is switched off, it is possible to vary the operating time envisaged by the timer in
STANDARD
mode between a minimum of 1
and a maximum of 99 hours.
Press the
VENT +
and
TEMP –
buttons at the same, the display shows the default value (6 h) and the clock and half snowflake symbols will light
up (see fig.3).
Quickly pressing the
VENT +
or
VENT –
button increases or reduces the value by 1 hour each time the button is pressed.
Pressing the same buttons for longer increases or reduces the value in steps of 10 hours.
Also with the system switched off it is possible to change the operating hours envisaged by the timer in
TURBO
mode in the same way.
Press the
VENT –
and
TEMP +
buttons at the same, the display to show the default value (4 h) and the clock and full snowflake symbols will light
up (see fig.4).
Quickly pressing the
VENT +
or
VENT –
button increases or reduces the value by 1 hour each time the button is pressed.
Pressing the same buttons for longer increases or reduces the value in steps of 10 hours.
PROGRAMMED START FUNCTION
When the system is switched off, it is possible to set the programmed start of the system between 1 and 99 hours.
Quickly press the
TURBO
button, changes the value by 1 hour at a time and the clock symbol will light up (see fig.5).
Pressing the same button for more than 2 seconds changes the value in steps of 10 hours and the clock symbol will light up, remaining lit until
the system starts.
If you wish to deactivate the function, press the
TURBO
button until a value of 0 is reached, or switch on the system.
VENTIL ATION (FAN)
If the fan increase or reduction buttons (
VENT +
or
VENT –
) are pressed when the system is switched off, only the evaporator fan is activated,
with the choice of 6 different speeds, shown on the central control unit display.
To switch off the fan it is necessary to set the value 0 on the central control unit display, using the fan speed reduction button (
VENT –
).
Содержание Sleeping Well BACK
Страница 2: ......
Страница 4: ......
Страница 34: ...SW BACK TOP SW_BACK TOP_28 02 2019 34 ...
Страница 54: ...SW BACK TOP SW_BACK TOP_28 02 2019 54 ...