Miscellaneous Problems
Symptom
Probable Cause
Solution
Dipswitch SW202 position 4 is in
the on position.
Set position 4 of SW202 to off.
Press start to exit.
Unable to exit Operator Menus.
Test switch wired from the I/O
board is closed.
Verify satellite test switch is not
closed.
No 120 volts A.C. power going to
the light fixture.
Verify A.C. voltage to the light
fixture.
Defective fluorescent light.
Replace fluorescent light.
Defective starter
Replace the starter.
No fluorescent light
Defective ballast.
Replace the ballast.
Coin Meter is not working
Defective Coin Meter
Replace with a known good one.
Not wired properly
Connect one lead to +5 or +12 volts
depending on device. The other lead
to count 1 on the JAMMA connector.
Defective I/O board