It is imperative that the refractory concrete within the unit is cured prior to use. Failure to do so will void the warranty and
may damage the machine. Please ensure that the air/fuel flow settings on the burner are set correctly (the flame should
be clean without any black smoke) and fuel pipework is free from leaks. During this process, it is normal to have
steam/water coming out of the incinerator.
Burners can be turned on/off from control panel. To start curing process, set primary airflow to 3.5 and secondary airflow
to 1. Please note that only primary burner should be turned on and secondary burner must be permanently off during this
exercise.
Curing is carried out using the following temperature set points as ordered in the procedures below;
Inciner8 Limited. Company Registered in England & Wales - REG: 04866401
VAT Registration: 855999544
Enter the world of:
www.inciner8.com
+44 (0) 1704 884020
Leading Provider of Thermal Treatment Solutions
Refractory Curing
YOU MUST FOLLOW THIS PROCESS
Advice
Following the curing process, you will see hairline cracks and minor scaling in the concrete which is completely normal.
Cracks wider than 2 mm should be treated using High Temp Black Mastic.
Congratulations, your incinerator is now cured.
Set Temperature 100°C
Primary Burner ON 5 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 100°C
Primary Burner ON 5 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 200°C
Primary Burner ON 15 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 200°C
Primary Burner ON 15 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 300°C
Primary Burner ON 30 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 300°C
Primary Burner ON 30 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 400°C
Primary Burner ON 60 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 400°C
Primary Burner ON 60 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 400°C
Primary Burner ON 120 Minutes
Primary Burner OFF 15 Minutes
Set Temperature 450°C
Primary Burner ON 60 Minutes
Set Temperature 500°C
Primary Burner ON 60 Minutes
Set Temperature 550°C
Primary Burner ON 60 Minutes
Set Temperature 600°C
Primary Burner ON 60 Minutes
Set Temperature 650°C
Primary Burner ON 60 Minutes
Set Temperature 700°C
Primary Burner ON 60 Minutes
Set Temperature 750°C
Primary Burner ON 60 Minutes
Set Temperature 800°C
Primary Burner ON 60 Minutes
Set Temperature 850°C
Primary Burner ON 60 Minutes