7
5
Specifications
Model
Product dimensions (W,D,H mm)
ARBC90TBS
900mm × 500mm × 548-1028mm
Model
Extraction
Other features:
ARBC90TBS
1000m3/hr extraction
– 4 speed invisible touch contorl
– 2 × 1.5 LED lights
– 3 × Baffle filters
YOUR RANGEHOODS
Rangehood components
Your Airvolution Canopy Rangehood is supplied with:
– 1 × Rangehood
– 1 × Expandable 150mm ducting adapter
– 1 × Packet of fasteners and wall plugs
– 2 × Stainless Steel flue pieces (upper and lower)
– 1 × Wall Bracket (“hook”) for the rangehood
– 1 × Wall Bracket for the inside of the chimney pieces
– 1 × “Outside Chimney” bracket
Typical installation tools required
You’ll most likely require the following tools/equipment
(not supplied) for the installation of your rangehood.
– Electrical drill
– Tape Measure
– Screw-driver
– Spirit Level
If ducting your rangehood, you’ll also most likely require:
– Jig saw
– Ladder
– Duct-tape
– Ducting
Your InAlto Rangehood
Expandable 150mm pipe
Box Canopy Rangehood is supplied with:
4 speed touch controls
61
8
Through your wall
Further to your various ducting options, below are some
tips on how to correctly duct your rangehood:
– Always use correctly sized ducting
— DO NOT reduce the size of the ducting
– Always use solid ducting
– Always use non-flammable ducting
– Always duct to the outside atmosphere
– Do not use flexible ducting
– Do not duct into the ceiling space- always vent to the
outside atmosphere.
– Avoid sharp 90 degree bends as much as possible,
use 45 degree bends instead wherever possible
– Duct to the outside atmosphere using the shortest
duct run possible
– Use cylindrical ducting whenever possible
Positioning the rangehood
Installation heights
– Over gas and electric cookers, Airvolution
recommends our rangehoods to be mounted
at a height of between 600-800mm above the
cooking surface.
– Electric cooktops must have a minimum height of
600mm from the underside of the rangehood to the
cooktop face.
– Gas cooktops must have a minimum of 650mm from
the burner to the underside of the rangedhood.
– It is not recommended to install the rangehood
outside or over open flame grillers or barbecues.
Installing the rangehood
See illustration below
– Once you’ve determined your installation height,
drill 3 holes to install the mounting bracket (hook)
onto the wall ensuring that it’s secured in a level
position, Tighten the bracket with the screw plug and
screw (ST4mm X 30mm).
– When finished, line up the hood and hang onto the
wall bracket hook. (See pic A )
– Attach the extensible 150mm tube to the canopy.
Put the inside chimney with the outside chimney
together, ensure that the inner chimney piece can
move freely inside. Now attach the chimney to the
hood. When finished, fix the outside chimney to the
canopy, mark the hole and drill 2 holes, then tighten
the outside chimney bracket with screw plug and
screw (ST4mm X 30mm). (See pic B )
If you need the safety screws fixed into the hood,
please mark, drill and tighten the hood with screw
plug and screw (ST4mm X 30mm). Note, you will
need to remove the grease filters first. (See Pic C )
– Slide the inner chimney to adjust the inner chimney
height. When the height you required is reached,
mark it and accommodate the inner chimney bracket
with screw plug and screw (ST4mm X 30mm).When
finished, fix the inner chimney with the screws (4mm
X 8mm) to the inner chimney bracket . (See pic C )
Warning
Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards. The warning shall be in the same
part of the instructions that include details of how
to mount the equipment.
INSTALLATION INSTRUCTIONS
CONTINUED