![In-situ 0034390 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/in-situ/0034390/0034390_manual_2050330013.webp)
800-446-7488
13
www.in-situ.com
Email (SMTP) communications can only be achieved by sending data without SSL encryption.
8. Enter the email address you'd like to receive the email from (must be a valid address), the address to receive email, and a
carbon copy address if desired.
9. Click
Write options and parameters
.
10. Close the window.
Activate Alarms
1. Click
General information, parameters and functional options
.
2. Click the
Alarms
tab.
3. Select the alarms you wish to activate. To activate alarms that are dependent on probe parameter readings, select "Reading
from probe out of range."
4. Under the "Alarm options" heading, select whether to send alarms using SMS (text) messages when they occur, then select
whether to send alarm statuses each time the Cube sends measurement values. Email alarms require an SMTP server that allows
login without authentication.
5. Enter the number of consecutive times a parameter in Absolute alarm mode can exceed its threshold before an SMS message is
generated. A value of 1 means an SMS message is generated every time.
6. Enter the number of consecutive times a parameter in Incremental alarm mode can exceed its threshold before an SMS
message is generated. A value of 1 means an SMS message is generated every time.
7. Enter the maximum number of text messages to be sent for the same Alarm episode.
8. Enter the maximum number of alarms that can be sent per day.
9. Click
Write alarm parameters
.
10. Close the window.
Set Probe Reading Schedule
1. Click
Frequency of wake-up events
.
2. Click
Frequency of probe readings and options
.
3. Select how often in minutes the Cube reads the probes. A value of 0 means the Cube never reads the probes, a value of 60
means every hour, and a value of 1440 means a reading every 24 hours.
4. Select how often the Cube saves the readings. A value of 1 means every reading.
5. Select how often the Cube transmits the readings. A value of 1 means every reading.
6. Select the significant digits to be included in the data.
7. Click
Write frequency and options
.
8. Close the window.
Set Wake Up Events
The Cube can be programmed with up to 8 different wake up periods. A wake up period is when the Cube sends data, sends a
status text message, or waits for an external connection.