MNEMONIC
FUNCTION
TYPE
V M
Maximum Velocity Variable
Motion Variable
DESCRIPTION
The VM variable specifies the maximum velocity in counts per second that the axis will reach during a move command
USAGE
UNITS
RANGE
DEFAULT
VM=<velocity>
Counts per sec
1 to 5000000
768000
EXAMPLE:
VM=51200
‘set max velocity to 51200 counts per second
RELATED COMMANDS: VM
MNEMONIC
FUNCTION
TYPE
VR
Read Only Firmware Version
Factory Variable
DESCRIPTION
This variable is used in conjuction with the PR instruction to read the version of the firmware installed at the factory. If the Version
number is followed by an E, the Mdrive is an Encoder Version. An I will indicate and Index version. Blank will indicate no options.
USAGE
PR VR
RELATED COMMANDS: —