![IMS 17 Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/ims/17/17_operating-instructions-manual_2049859052.webp)
50
MNEMONIC
FUNCTION
TYPE
M D
Motion Mode
Motion Instruction
DESCRIPTION
Indicates what the last motion command was, so that when just a number is entered, then it will read MD to define the new motion.
USAGE
MD
EXAMPLE:
MA 200000
‘move absolute 200000 steps, set current mode to MA
-200000
‘move absolute -200000 steps
MR 1000000
‘move relative 1000000 steps, set current mode to MR
-1000000
‘move relative -1000000 steps
SL 20000
‘slew 20000 steps/sec. set current mode to SL
-10000
‘slew 10000 steps/sec in minus direction
PR MD
return current mode setting
RELATED COMMANDS: MD, MR, MS, P, PR, SL
MNEMONIC
FUNCTION
TYPE
MR
Move To Relative Position
Motion Instruction
DESCRIPTION
Set mode for relative move and move a relative distance. MD (Current Mode) will be set to MR.
USAGE
UNITS
MR <±distances>
motor counts
EXAMPLE:
MR 200000
‘move motor to 200000 motor counts postive direction
MR -50000
‘move motor to 50000 motor counts in a negative direction
RELATED COMMANDS: MD, MA, MS, P
MNEMONIC
FUNCTION
TYPE
MA
Move To Absolute Position
Motion Instruction
DESCRIPTION
Set mode for absolute move and move to an absolute position. MD (Current Mode) will be set to MA.
USAGE
UNITS
MA <±pos>
motor counts
EXAMPLE:
MA 51200
‘move motor to absolute position 51200 in positive direction
MA -51200
‘move motor to absolute position 51200 in negative direction
RELATED COMMANDS: MD, MR, MS, P
Содержание 17
Страница 1: ...OPERA TING INSTRUCTIONS T intelligent motion systems inc Excellence in MotionTM TM ...
Страница 5: ...3 Part 1 General Information and Hardware Specifications ...
Страница 6: ...4 Intentionally Left Blank ...
Страница 19: ...17 Part 2 Connecting Configuring and Programming the MDrive Motion Control ...
Страница 20: ...18 Intentionally Left Blank ...