background image

Check contents of the pack before installation. If there is anything missing, contact our Technical Helpline Number for assistance.

The fixings may be spread across several packs - please check the contents of each pack carefully. 

Screw 

cover cap

2 & 3mm 

Allen keys

PN50247

PN4745

PN60162

PN50266

Top cap

Corner 

joint cap

Shower  

panel foot

Top  

panel 

bracket

Plastic 

threshold 

strip

PN80501

PN80500

*

PN10785

2

2

1/2

1

1

1/2

2

0

2

1

0

1

32mm

Screw

Tie bar 

bracket

PN8212

PN8203

PN80499

PN40166

PN60210

Wall plug

Tie bar 

bracket

Washer

2

2

0

0

2

5

5

4

0

1

10

10

8

2

4

5

5

4

1

1

OPTIONS:

5

4

2 3

OPTIONS:

5

4

2 3

OPTIONS:

1

1

1

1

0

1

1

0

5

5

4

PN40177

Aluminium 

threshold 

strip

1

1

5

4

5

6

PN80506

Seal

0

2

4

2

2

2

*1

*1

0

Note:

 The quantities of the threshold 

strips will depend on size of panels. 

*

Optional Extras, not included in pack.

6

Note:

 The 

*

Spacer Plate PN80573 50 

is only included with option 6.

Note:

 The 

*

Spacer Plate PN80583 is 

only included with option 6.

AQUA SCREEN PURE

PAGE 1

71399 00 / Issue 11 / 16

TECHNICAL HELPLINE: 01460 258682

5

4

2 3

2

2/4

0

1/1

1

1/2

1

1/1

0

2

2

1/1

0

1

1

1/1

1

1

0

1/1

1/2

1

0

1/1

6

Please read these instructions carefully and keep for future reference. 
Incorrect fitting will invalidate the guarantee.

SAFETY

● 

Handle glass with care. Although the glass is very tough, sharp impacts can damage 
both the glass and metal frame.

  Do not remove the plastic corner protectors from the glass panels until the panels  

are about to be fitted.

● 

As the parts are large, we recommend that two people are needed to carry out parts  
of the installation.

● 

Make sure there are no hidden pipes or cables in the floor and walls where you  
intend to drill.

● 

Wear safety goggles, shoes and appropriate clothing.  

BEFORE INSTALLATION

● 

The panel/s will not sit correctly on an uneven surface. If uneven, the wall  
channels may not fit. 

● 

Note:

 

If not fitted on a tray, ensure panel/s are fitted to a tiled or waterproof 

composite floor.

● 

The panel/s should be fitted on tiled walls which are sealed with waterproof grout. 

● 

Always check very carefully that components are vertical.

EQUIPMENT NEEDED:

Drill, 4mm & 6mm Masonry Bits, Crosshead Screwdriver, Flatblade Screwdriver (small & 
medium), Spirit Level, Pencil, Fine Tooth Saw, Silicone Sealant, Scissors, Masking Tape,  
Tape Measure.

Note:

 The screws and wall plugs supplied are for masonry walls. For lightweight walls  

i.e. stud partitions, plasterboard etc, use the correct type of fixings.

OPTION 1 - 

PAGES 2 - 4

OPTION 4 - 

PAGES 9 - 13

OPTION 3 - 

PAGES 5 - 8

OPTION 2 - 

PAGES 5 - 7

OPTION 5 - 

PAGES 14 - 17

OPTION 6 - 

PAGES 18 - 20

OR

*

*

Содержание AQUA SCREEN PURE

Страница 1: ...uture reference Incorrect fitting will invalidate the guarantee SAFETY Handle glass with care Although the glass is very tough sharp impacts can damage both the glass and metal frame Do not remove the...

Страница 2: ...outside of the panel Satin glass patterns MUST be installed to the outside of the panel Note The Glass Guard coating is on the opposite side to the label or satin glass patterns 5 4 If using the thre...

Страница 3: ...6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same width as the panel Measure the height of the threshold strip X and remove the same amount off each...

Страница 4: ...ie bar g From inside tighten the grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push f...

Страница 5: ...he correct way around into the wall channel Note Wetting the edge of the panel with water will help the panel insert If not using the threshold strips proceed straight to step 7 4 If using the thresho...

Страница 6: ...position of the angled tie bar bracket onto the wall Approx 250mm PN80499 PN80499 3mm 2mm 2mm 6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same widt...

Страница 7: ...he grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Tighten the large screws on both of...

Страница 8: ...PN10754 Wall channel PN10754 1 Plan position of panels The size of the opening will depend on the tray if used or the site conditions To fit the DOUBLE PANEL WITH ANGLED TIE BARS option follow the sam...

Страница 9: ...ss Guard coating is on the opposite side to the label or satin glass patterns Tie bar PN10786 Wall channel PN10754 Corner joint PN11011 5 4 If using the threshold strip s there are 2 types available A...

Страница 10: ...r joint short side as shown onto the main panel b Carefully measure and trim your chosen threshold strip down to the width of the panel minus the corner joint c Measure the height of the threshold str...

Страница 11: ...Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push fit the top cap onto the top of the wall channel 32 mm a 1 2...

Страница 12: ...oot so it is flush with the underside Place the inner foot into the foot Position the assembled foot under the return panel flush with the edge d Ensure the return panel is vertical and if required ad...

Страница 13: ...ling foot to floor Use the allen key to remove the pin from the inner foot Apply silicone sealant to the underside of the inner foot Position the assembled foot in the marked position b 15 Apply silic...

Страница 14: ...e wall b If required trim the tie bars to length X 50mm c Assemble the tie bars slide on the top panel brackets and tie bar brackets Lightly tighten the fitted grub screws X Wall Opening X 50mm a b c...

Страница 15: ...e tie bars 2 Push fit the screw cover caps 32 mm a c d b 2mm 1 2 g Inside 3mm 5 a Carefully place the tie bar assemblies onto the glass approximately 100mm from the edges depending on your installatio...

Страница 16: ...el c Use the 3mm allen key to wind up the pin on each inner foot so they are flush with the underside Place the inner feet into the feet Position the assembled feet under the return panels flush with...

Страница 17: ...hole Position the assembled feet in the marked position Option b Sealing feet to floor Use the allen key to remove the pins from the inner feet Apply silicone sealant to the underside of the inner fee...

Страница 18: ...nel with water will help the panel insert 6 mm a b d 32 mm 1180mm max c PN80499 PN80499 PN80506 5 4 Ensure that the open end of the panel is vertical and the panel is parallel with the opposite wall W...

Страница 19: ...ten the large screws on both tie bar brackets 7 Push fit the top cap onto the top of the wall channel 32 mm a 1 2 c d g Inside b 3mm 2mm 8 Foot Options Option A Without foot follow step 10 Option B Wi...

Страница 20: ...contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre TECHNICAL HELPLINE 01460 258682 PAGE 20 10 Seal along th...

Отзывы: