Alarm displays:
Temp.sens.water
Defective sensor in the drinking water system
Temp.sens.supply
Defective sensor in the drinking water supply line
Max.temp.flushing
The maximum number of flushes based on temperature has been reached
Max.dirt.flushing
The maximum number of flushes based on pollution has been reached
No water
The water detection sensor indicates no water present
No water pressure
The water pressure sensor indicates too low water pressure
Max. water/minute
The water meter indicates the amount of water per minute is above the allowed
maximum
General menu
Select the main screen and press the
key. Select “General” and press the
key. The following
settings/measurements are displayed:
Mode
(time, temp, dirty, ti+tem, ti+dir, te+dir, t+t+di)
This setting determines the I-Control response with the following options:
Time
(Time)
The I-Control automatically starts flushing at the programmed time.
Temp.
(Temperature)
The I-Control automatically starts flushing when the temperature is too high.
Dirty
(Dirt) The I-Control automatically starts flushing when drinking water pollution is detected.
Ti+Tem
(Time + Temperature)
The I-Control automatically starts flushing at the programmed time or
when the temperature is too high.
Ti+Dir
(Time + dirt) The I-Control automatically starts flushing at the programmed time or when drinking
water pollution is detected.
Te+Dir
(Tempe dirt) The I-Control automatically starts flushing based on temperature or
pollution detection.
T+T+Dir
(Tempe Time + dirt) The I-Control automatically starts flushing at the programmed time
or temperature or pollution detection.
Note:
Depending on the selected options in the installer’s program, not all the above options can be selected.
Note:
With minimal configuration (only flushing on a time basis), this function will not be displayed.
Tempor.off
(00:00 to 23:59 hours)
With this setting, the I-Control can be temporarily inactivated. Flushing automatically resumes at the end of the
programmed time. For example, this function is used when adding medicines to the drinking water when flushing
is temporarily undesirable.
Note:
This setting is also accessible by the shortcut 5 (
'
STOP').
Start time
(00:00 to 23:59 hours)
The I-Control is only active between a set start and stop time. This is important when the water supply in the
house is controlled, for example by
a climate computer. When the water supply is shut off during the night, it is
not possible to flush. This function determines the time from which the I-Control is active.
Note:
When the I-Control is to be active throughout the day, set the start time at 00:00 hours and stop time at
23:59 hours.
Stop time
(00:00 to 23:59 hours)
The I-Control is active until the set time is reached. For further explanation, see previous function.