I-Control manual
page 13
Installer’s manual
The installer’s program is used to adjust the I-Control to the specific requirements of the user. Several tasks can be
set so that only the functions relevant to the user are displayed. Unused functions will not be displayed.
Booting the installer’s program
Push the
key in the main menu. The I-Control requires the PIN-number. Enter the correct PIN-number and
press the
key. The installer’ menu will be displayed.
PIN-number: 2826
By using the
and
key, the items can be scrolled through in this menu. Press the
key to select an
item.
The cursor keys
and
are used to scroll through all the functions of the selected menu. A setting is
adjusted by pressing the
key. This setting will be displayed in a new window, and a new value can be
entered. By pressing the
again, the new value is stored in the memory.
General
Select this menu by pressing “General” in the installer’s program and press the
key. This menu displays the
general installer’s settings.
Language
(English, Dutch)
This function determines the language used. The options are English and Dutch with additional languages to be
added in the future.
No. of valves
(1 to 10 valves)
This function specifies how many flush groups will be are used. The main screen for the user will be adapted
accordingly. Some functions will be limited to the maximum number of flushing groups.
Temperature
(off, on)
This function indicates whether or not the temperature control is used to start flushing. By turning this setting to
OFF, the temperature control is not used, and the temperature menu will not be displayed. It is therefore
unnecessary to connect temperature sensors.
D-sensor
(off, on)
By turning this setting to ON, automatic flushing starts when the water becomes polluted. It is therefore necessary
to install a dirty water detection sensor. By turning this setting to OFF, the dirt detection menu is not be displayed.
Curves
(off, on)
When curves are to be used, press ON. When set to OFF, the curves are neither in operation nor displayed.
Default curve
(0 to 5)
The curve can be set with specific default values. There are five standard curves, which can be optionally modified
by the installer. If this setting is set to a standard curve (1 to 5), this standard curve is copied to the curve of the
user by I-Control, and this setting returns to 0.