Tiger CCD Cameras with Camera Link
– User Manual
November 27, 2017
Page
83
of
86
Rev 1.0
Pulse Generator Registers
Address
Register
Name
Data
Type
Description
0x0530
Pulse
Generator
Timing
Granularity
Data (1:0)
0x0
–
x1
0x1
–
x10
0x2
–
x100
0x3
–
x1000
Data (31:2)
N/A
RW
Sets pulse generator
main timing resolution.
0x0534
Pulse
Generator
Pulse Width
Data (23:0)
<value>
–
pulse width in
microseconds
Data (31:24) N/A
RW
Sets value of pulse width
in microseconds.
0x0538
Pulse
Generator
Pulse Period
Data (23:0)
<value>
–
pulse width in
microseconds
Data (31:24) N/A
RO
Sets value of pulse
period in microseconds.
0x053C
Pulse
Generator
Number of
Pulses
Data (15:0)
<value>
–
number of discrete pulses
Data (16)
0x1
–
continuous pulse gen.
Data (31:17) N/A
RW
Sets number of pulses
generated.
0x0540
Pulse
Generator
Enable
Data (0)
0x0
–
disable pulse gen. operation
0x1
–
enable pulse gen. operation
Data (31:10) N/A
RW
Enables pulse generator.
Test Pattern Workspace Registers
Address
Register
Name
Data
Type
Description
0x012C
Test
Mode
Select
Data (3:0)
0x0
–
no test pattern
0x1
–
BW checkerboard
0x2
–
gray image
–
user selectable value
0x3
–
tap segmented (each tap has a fixed value). Tap
A
–
0xAAA, Tap B
–
0xBBB, Tap C
–
0xCCC, Tap D
–
0xDDD
0x4
–
steady horizontal image ramp
0x5
–
steady vertical image ramp
0x6
–
steady vertical & horizontal image ramp
0x7
–
moving vertical & horizontal image ramp
0x8
–
8 gray scale vertical bars
0x9
–
Center cross superimposed over live image
0xA to 0xF - reserved
Data (31:4) N/A
RW
Selects test
mode
pattern.
Output Registers
Address
Register
Name
Data
Type
Description
0x0590
0x0598
OUT 1
Polarity
OUT 2
Polarity
Data (0)
0x0
–
active LOW
0x1
–
active HIGH
Data (31:1) N/A
RW
Sets polarity (active
Low or High) for
OUT1 or OUT2
output.