Tiger CCD Cameras with Camera Link
– User Manual
November 27, 2017
Page
74
of
86
Rev 1.0
Appendix B
– Camera Registers
B.1 Camera RGS Space Structure
Abbreviation
Description
RW
read/write
RO
read only
WO
write only
RW1C
Read/write-1 to clear
B.1.1 Camera Local Space
Saving and Restoring Settings
Operational settings for the camera are stored in non-volatile FLASH memory. Five separate configuration
spaces exist (see Camera Factory Space above).
Address Register Name
Data
Type
Description
0x5000
Boot From
Register
Data (2:0)
0x0
–
Factory
0x1
–
User 1
0x2
–
User 2
0x3
–
User 3
0x4
–
User 4
0x5 to 0x7 - reserved
Data (31:3) N/A
RW
Sets default selector determining the
configuration space to load following a
power cycle or reset.
0x6060
User Set
Selector
Data (2:0)
0x0
–
Factory
0x1
–
User 1
0x2
–
User 2
0x3
–
User 3
0x4
–
User 4
0x5 to 0x7 - reserved
Data (31:3) N/A
RW
Determines FLASH sector which will be
loaded into the camera workspace or
saved from workspace.
0x6064
User Set Load
From
WO
Loads workspace from selected User
space or Factory Space as defined by
register 0x6060 contents.
0x6068
User Set Save
To
WO
Saves workspace to selected User space
as defined in register 0x6040.