Cheetah Pregius Camera with GigE Vision
®
Interface – User Manual
August 27, 2019
Page
54
of
123
Rev 1.0
Acquisition Control
Acquisition Control lets you configure settings for image capture, exposure, frame rates,
triggers, and so on. It also provides read-only information on frame and exposure time.
Table 23:
Acquisition Control parameters
Parameter Name
Type
Value
Access Description
AcquisitionMode
Enumeration
String
"SingleFrame"
"MultiFrame"
"Continuous"
Num
.
0
1
2
RW
Defines the number of
frames to capture during
acquisition and the way
the acquisition stops
(refer to
section for more
information)
AcquisitionStart
Command
WO
Starts device acquisition
AcquisitionStop
Command
WO
Stops acquisition after
current frame completes
readout.
AcquisitionAbort
Command
WO
Stops acquisition
immediately, but a
partially transferred
image will be completed
AcquisitionFrameCount
Integer
Min: 1
Max: 65535
RW
Number of Frames to
acquire in Multi-Frame
Acquisition mode
ExposureMode
Enumeration
String
"Off"
"TriggerWidth"
"Timed"
Num.
0
1
2
RW
Sets exposure mode.
“Off”: exposure time
equals frame time (refer
for more information)
ExposureTime
Float
RW
Sets Timed Exposure in
micro-seconds when
ExposureMode is Timed
and ExposureAuto is
“Off”.
AcquisitionFrameRateEnable
Boolean
RW
Controls if the
AcquisitionFrameRate
and
AcquisitionFrameTime
features are writable and
used to control the
acquisition rate. If “On”,
you can extend the
actual frame time
beyond the free-running
frame time.
AcquisitionFrameTime
Integer
RW
Sets Frame Time in
microseconds. 16
seconds maximum.