Chapter 4 Software index
4-7
b78
Serial Communications Baud Rate
000: 4800 (bps)
001: 9600
002: 19200
003: 38400
003 *3
*4
b79
Stop Bits
000: 1 Bit
001: 2 Bits
000 *3
*4
b80
Parity Bit
000: No Parity
001: Even Parity
002: Odd Parity
000 *3
*4
b81
Data Bits
000: 8 Bits
001: 7 Bits
000 *3
*4
b82
Communication Error Detection Time
00.0 ~ 25.5 (s)
00.0
*3
b83
Communication Error Response
000: Decelerate to Stop (A05)
001: Coast to Stop
002: Decelerate to Stop (b01)
003: Continue to Run
000 *3
b84
Remote Keypad Frequency Control (by)
000: UP/DOWN Keys
001: Potentiometer (VR)
000
b85
Remote Keypad – Enable / Disable
(and action if keypad cable fault)
000: Remote keypad disabled
001: Remote keypad enabled
(Motor stopped as set by b92)
002: Remote keypad enabled
(No stop, runs at Set Freq)
000
b86
Carrier Frequency
004 ~ 016 (kHz)
010
b87
Inverter Cooling Fan
000: Auto Run by Inverter °C
001: Run When Output On
002: Always Run
003: Always Stop
001
IP20
Only.
b88
Motor Rotation Direction
000: Forward
001: Reverse
000 *1
b89
Inverter Power Code (Read Only)
See following description
b90
RUN / STOP / Direction Switching
000: FWD/STOP-REV/STOP
001: RUN/STOP-FWD/REV
002: 3-Wire – RUN/STOP
000
b91
Reverse RUN Instruction
000: Reverse Enabled
001: Reverse Disabled
000
b92
STOP Method
000: Decelerate to STOP
001: Coast to STOP
000
b93
Operation Monitor
000: Display Hz Only
001: Display Hz, A, V, PID, etc
000
b94
Copy Module
000: Module Disabled
001: Copy
iDrive
to Module
002: Copy Module to
iDrive
003: Read / Write Check
000 *3
b95
All Data Reset to Factory Settings
010: Reset to Default (50Hz)
020: Reset to Default (60Hz)
000
b96
Software Version (Read Only)
CPU Version
*3 *4
b97
Alarm Log
Last 3 fault records
*3 *4