Chapter 3 Environment description and installation
3-17
Over load protection Inverter rated current 150%/1min
International
conformity
UL/cUL/CE
Over-voltage trip
200V Class: DC voltage >400V. 400V Class: DC voltage >800V
Under-voltage trip 200V Class: DC voltage <190V. 400 Class: DC voltage <380V
Instantaneous
power-loss restart
Set to enable or disable
Stall prevention
ACC/DEC/ Operation stall prevention and stall prevention level.
Output terminal
short circuit
Electronic circuit protection
Other faults
Electronic circuit protection
Protective Functions
Other function
Over-current, over-voltage, under-voltage, overload, instantaneous power-loss
restart, ACC/DEC / RUN stall prevention, output terminal short circuit,
grounding error, reverse block, direct start at power on and fault reset limit.
※1
:
The setting resolution above 100Hz is 1Hz when set by keypad, and 0.01Hz when set using
serial communication from computer (PC) or programmable controller (PLC).
※2
:
Non-standard, un-filtered
iDrive
model numbers
EDX-020-21
to
EDX-075-21
, and
EDX-075-
43
to
EDX-220-43
fitted with optional external filter are in accordance with EN61800-3 First
Environment; Unrestricted Distribution when carrier frequency is set at 10KHz or less.
Non-standard, un-filtered
iDrive
model numbers
EDX-150-21
and
EDX-220-21
, fitted with
optional external filter are in accordance with EN61800-3 First Environment; Unrestricted
Distribution when carrier frequency is set at 10KHz or less.
Standard, filtered
iDrive
model numbers
EDX-020-21-E
to
EDX-075-21-E
, are in accordance
with EN61800-3 First Environment; Restricted Distribution when carrier frequency is set at
10KHz or less.
Model numbers
EDX-150-21-E
and
EDX-220-21-E
are in accordance with EN61800-3 First
Environment; Restricted Distribution when carrier frequency is set at 6KHz or less.
IP65 / NEMA4
iDrive
models
EDX-020-21-E-N4(S)
to
EDX-220-21-E-N4(S)
and
EDX-075-
43-E-N4(S)
to
EDX-220-43-E-N4(S)
are in accordance with EN61800-3 First Environment;
Restricted Distribution when carrier frequency is set at 10KHz or less.