19
1-29
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1.25 KITS AVAILABLE ON REQUEST.
• System shut-off valve kits with or without
inspection filter (on request). The boiler is
designed for installation of system interception
cocks to be placed on flow and return pipes
of the connection assembly. This kit is very
useful for maintenance because it allows to
empty just the boiler without having to empty
the entire system. Moreover, the version with
filter preserves the functioning characteristics
of the boiler thanks to its inspectionable filter.
• System zone control unit kit (on request). If
the heating system is to be divided into several
zones
(max. three),
in order to interlock them
with separate adjustments and to keep water
flow rate high for each zone, Immergas supplies
zone system kits by request.
• Polyphosphate dispenser kit (on request). The
polyphosphate dispenser reduces the forma-
tion of lime-scale and preserves the original
heat exchange and domestic hot water pro-
duction conditions. The boiler is prepared for
application of the polyphosphate dispenser kit.
• Relay board (on request). The boiler is prepared
for the installation of a relay card that allows
to increase the features of the appliance and
therefore functioning possibilities.
• Cover kit (on request). If installed outdoors in a
partially protected place with direct air intake,it
is compulsory to mount the appropriate top
protection cover for the correct functioning
of the boiler and to protect it from adverse
weather conditions.
• Recirculation kit (on request). The boiler
storage tank unit is prepared for application
of the pump kit. Immergas supplies a series of
fittings and attachments that allow connection
between the storage tank unit and domestic hot
water system. The pump kit attachment is also
envisioned on the template.
The above-mentioned kits are supplied complete
with instructions for assembly and use.
Key:
1 - System filling valve
2 - Condensate drain trap
3 - System draining valve
4 - Gas valve
5 - Three-way valve (motorised)
6 - 3 bar safety valve
7 - System pressure switch
8 - Boiler circulator pump
9 - Vent valve
10 - Fan
11 - Gas nozzle
12 - Venturi
13 - Detection electrode
14 - Condensation module
15 - Air intake pipe
16 - Flue probe
17 - Sample points (air A) - (flue gas F)
18 - Negative signal pressure point
19 - Burner
20 - Positive signal pressure point
21 - Manual air vent valve
22 - Ignition electrodes
23 - System expansion vessel
24 - Flow probe
25 - Safety thermostat
26 - Domestic hot water probe
27 - D.H.W. expansion vessel
28 - Return probe
29 - Stainless steel storage tank
30 - 8 bar safety valve
31 - Storage tank unit draining valve
32 - Adjustable by-pass
1.26 BOILER COMPONENTS.
Содержание VICTRIX ZEUS SUPERIOR
Страница 1: ...VICTRIX ZEUS SUPERIOR 26 2 32 2 ERP Instruction and recommendation booklet IE 1 037935ENG...
Страница 2: ......
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...